Control Panel Test (6-7: OPERATION PANEL)
This test is used to check the operation of the control panel.
A press on '7' on the keypad from the control panel selects the OPERATION PANEL Test
menu, enabling the following tests:
Display Test
A press on the Start key on the OPERATION TEST PANEL Test menu selects the dis-
play test. In this test, the message 'ADJUST LCD CONTRAST' is indicated on the dis-
play.
Another press on the Start key will indicate the character H and turn the display totally
black.
LED Lamp Test
A press on the Start key after the display test selects the LED lamp test, turning all
lamps in the control panel to go ON.
Control Key Test
A press on the Start key after the LED lamp selects control key test 1. Press the key in-
dicated on the display; if it goes out, the operation is normal.
When all characters have gone out, control key test 2 (if equipped with fax functions) is
started. As in the case of operation key test 1, press the key indicated on the display; the
operation is correct if it goes out.
Key Correspondence for Control Key Test 1 (if not equipped with fax functions)
COPYRIGHT © 2001 CANON INC.
Chapter2.p65
[E]
[A]
Additional Functions
Collate
2 on 1
Set
Enlarge/Reduce
Paper Select
Exposure
Image Quality
[J]
[H]
[D]
[F]
[I]
[G]
F02-319-15
CANON imageCLASS D600s/PC1060s/PC1200s/iR1200s REV. 0 SEPT. 2001
71
CHAPTER 2 USING THE MACHINE
[C]
In Use/Memory
Stop/Reset
ABC
DEF
GHI
JKL
MNO
PRS
TUV
WXY
OPER
SYMBOLS
TONE
????
[B]
8/26/01, 3:42 PM
Energy Saver
Alarm
Start
2-71

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pc1060sPc1200sIr1200s

Table of Contents