3.19.6.2 Frequency Test

A press on '2' on the keypad from the MODEM NCU Test menu selects the frequency
test. In this test, signals of the following frequencies from the modem are transmitted using
the telephone line terminal and the speaker. To select a different frequency, use the keypad.
Keypad
Keypad
Frequency
Frequency
1
1
462Hz
462Hz
2
2
1100Hz
1100Hz
3
3
1300Hz
1300Hz
4
4
1500Hz
1500Hz
5
5
1650Hz
1650Hz
6
6
1850Hz
1850Hz
7
7
2100Hz
2100Hz
The frequency and the output level of individual frequencies are in keeping
with the output level set in service mode.
Memo
3.19.6.3 G3 Signal Transmission Test
A press on '4' on the keypad from the MODEM NCU Test menu selects the G3 signal
transmission test. In this test, the following G3 signals from the modem are transmitted us-
ing the telephone line terminal and the speaker. To select a different transmission speed, use
the keypad.
Keypad
Keypad
Transmission speed
Transmission speed
0
0
300bps
300bps
1
1
2400bps
2400bps
2
2
4800bps
4800bps
3
3
7200bps
7200bps
4
4
9600bps
9600bps
5
5
TC7200bps
TC7200bps
6
6
TC9600bps
TC9600bps
7
7
12000bps
12000bps
8
8
14400bps
14400bps
The output level of individual signals is in keeping with the setting made in
service mode.
Memo
2-66