INSUFFICIENT RINSE
INSUFFICIENT DRYING
STAINED GLASSES AND
CUTLERY
WATER LEFT IN THE TANK
AFTER PUMP-OUT.
THE DISHWASHER DOES NOT
TURN ON, "OFF" APPEARS
ON THE DISPLAY and THE
SALT LIGHT FLASHES.
THE CHAMBER AND BOILER
HEATING ELEMENT LIGHTS
FLASH AT THE SAME TIME.
Improper set cycle
Clogged nozzles
Boiler incrusted with
limescale
Inappropriate rinse aid, or it
is not dispensed correctly.
Low rinsing temperature
Inappropriate rinse aid, or it
is not dispensed correctly.
Water hardness superior
than 12°dF or it contains
many dissolved salts.
Rinse aid unsuitable or not
being delivered correctly.
Water hardness above 12°dF
or large amounts of dissolved
salts
Waste tube badly positioned
or partially clogged.
The salt lock has activated
due to the lack of
regeneration salt.
CONFIGURATION FAULT
THAT PREVENTS THE WATER
FROM HEATING.
38
Increase the duration of the washing
cycle, especially if the load is very
dirty or partially dried.
- Verify that the nozzles are clean and
that the water softener, if present, is
working correctly.
- Verify that the filter of the tube
placed inside the rinse aid jerrycan is
not clogged.
Verify the rinse aid container and if it
is adequate to the type of mains
water.
Verify the boiler set temperature
Restore T Stop ON and/or connect
the machine to hot water.
If the problem is not solved, contact
the After-Sales Service.
Verify the rinse aid container and if it
is adequate to the type of mains
water. If the problem is not solved,
contact the After-Sales Service
Check container of rinse aid and
whether type is suitable for the
mains water- If the problem persists,
contact the after-sales service.
Verify that the tube and drainage are
not clogged and that the drainage is
not positioned too high; see
connection scheme.
Top up the regeneration salt.
CONTACT THE AFTER SALES SERVICE