Byte
Value
Ident profile, Add-on instruction for Rockwell systems
Function Manual, 07/2020, C79000-G8976-C410-04
RFID sys-
Meaning
tem
7 ... 5
This parameter switches the presence check on or off on the reader.
Possible values:
You can find information on the semaphore procedure in the product
information "Input parameters for the RF300 system".
1)
In "None present" mode, the LED of the reader stays blue until initial
access (Read/Write/Init) to the transponder takes place. The LED
flashes green as long as no other access is made or command is
executed. As soon as a command is sent, the LED lights up green or
orange, depending on whether or not a transponder is within the an-
tenna range.
0: Operation without presence check
Antenna is permanently switched on.
1: Operation with presence check
Antenna is permanently switched on.
2: RF300 (2nd Generation): Operation without presence check and
with semaphore procedure (RF300, ISO 14443 [MIFARE Classic,
MOBY E])
Antenna is permanently switched on.
3: RF300 (2nd Generation): Operation with presence check and
with semaphore procedure (RF300, ISO 14443 [MIFARE Classic,
MOBY E])
Antenna is permanently switched on.
4: Operation without presence check
Antenna is switched off. The antenna is only switched on when
one of the following commands is sent: Read, Write, Init, Tag-
Status
6: RF300 (2nd Generation): Operation without presence check and
with semaphore procedure (RF300, ISO 14443 [MIFARE Classic,
MOBY E])
Antenna is switched off. The antenna is only switched on when
one of the following commands is sent: Read, Write, Init, Tag-
Status
Note on LED behavior with MOBY I migration:
Configuring the instructions
4.6 Programming the Ident profile
1)
85