Siemens SIMATIC Ident Function Manual page 109

Hide thumbs Also See for SIMATIC Ident:
Table of Contents

Advertisement

Error mes-
Description
sage
(hex)
0xE5FE0100
Incorrect sequence number order (SN) on the reader/communications module
0xE5FE0200
Incorrect sequence number order (SN) in the Ident profile
Possible cause: User mode "Ident profile/RFID standard profile" is not set in the device configuration.
0xE5FE0400
Invalid data block number (DBN) on the reader/communications module
0xE5FE0500
Invalid data block number (DBN) in the Ident profile
0xE5FE0600
Invalid data block length (DBL) on the reader/communications module
0xE5FE0700
Invalid data block length (DBL) in the Ident profile
0xE5FE0800
The previous command is still active or the buffer is full.
A new command was sent to the reader or communication module although the last command is still
active.
The active command can only be aborted with "INIT".
Before a new command can be started, "DONE bit = 1" must be set (exception "INIT").
Two Ident profile calls were assigned the same "HW_ID", "CM_CHANNEL" and "LADDR" parame-
ter settings.
Two Ident profile calls are using the same pointer.
After eliminating the error, execute the "INIT" command.
When working with command repetition (e.g., fixed code transponder), no data is being fetched
from the transponder. The data buffer on the reader/communications module has overflowed.
Transponder data has been lost.
0xE5FE0900
The reader or communications module executes a hardware reset ("INIT_ACTIVE" set to "1"). "INIT" is
expected by the Ident profile (bit 15 in the cyclic control word).
0xE5FE0A00
The "CMD" command code and the relevant acknowledgment do not match. This can be a software
error or synchronization error that cannot occur in normal operation.
0xE5FE0B00
Incorrect sequence of acknowledgement frames (TDB / DBN)
0xE5FE0C00
Synchronization error (incorrect increment of "AC_H / AC_L" and "CC_H / CC_L" in the cyclic control
word). "INIT" had to be executed.
0xE5FE8100
Communication error between reader and communication module
Access denied
0xE5FE8200
Communication error between reader and communication module
Resource is occupied
0xE5FE8300
Communication error between reader and communication module
Functional error of the serial interface
0xE5FE8400
Communication error between reader and communication module
Other faults/errors
0xE6FE0100
Unknown command
The Ident profile sends an uninterpretable command to the reader.
Possible causes:
The "AdvancedCmd" block was supplied with an incorrect "CMD".
The "CMD" input of the "AdvancedCmd" block was overwritten.
Freeport: Incorrect command parameters or unauthorized command chaining (incorrect length speci-
fication)
0xE6FE0200
Invalid command index (CI)
Ident profile, Add-on instruction for Rockwell systems
Function Manual, 07/2020, C79000-G8976-C410-04
5.1 Error messages from the Ident profile / Ident instructions
Diagnostics and error messages
109

Advertisement

Table of Contents
loading

Table of Contents