Parameter
LEN_ID
MEM_BANK
PSWD
TXREF
Table 4- 54 READER-STATUS
Parameter
CMD
OFFSETBUFFER
ATTRIBUTES
RXREF
Table 4- 55 TAG-STATUS
Parameter
CMD
OFFSETBUFFER
ATTRIBUTES
EPCID_UID
Ident profile, Add-on instruction for Rockwell systems
Function Manual, 07/2020, C79000-G8976-C410-04
Value / description
0x00 ≙ unspecified single tag access
Length of the EPC-ID (2-62 bytes)
0x00 ≙ Reserved
Memory bank
0x01 ≙ EPC
0x02 ≙ TID
0x03 ≙ USER
0x00 ≙ no password
Password
Data to be written
Value / description
0x74
Offset in the "RXREF" receive buffer
Identifier of the status modes / possible entries:
RF200: 0x81
RF300: 0x81, 0x86
RF300 Gen2: 0xEF
RF600: 0x89
RF18xC/RF18xCI, RF166C: 0xA2
Received status data
You will find the data structure of the status modes in the section
"Reader_Status (Page 54)".
Value / description
0x73
Offset in the "RXREF" receive buffer
Identifier of the status modes / possible entries:
RF200: 0x83
RF300 (RF300T): 0x04, 0x82
RF300 (ISO): 0x83
RF300 Gen2: 0x83
Buffer for up to 62 bytes EPC-ID, 8 bytes UID or 4 bytes handle ID.
2 - 62-byte EPC-ID is entered at the start of the buffer (length
is set by "LEN_ID")
8-byte UID is entered at the start of the buffer ("LEN_ID = 8")
Configuring the instructions
4.6 Programming the Ident profile
77