Siemens SIMATIC Ident Function Manual page 84

Hide thumbs Also See for SIMATIC Ident:
Table of Contents

Advertisement

Configuring the instructions
4.6 Programming the Ident profile
The parameter values of bytes 9 ... 16 are described below.
Table 4- 72 Parameter values of bytes 9 ... 16
Byte
Value
Byte 9
scanning_
time
Byte 10
param
84
RFID sys-
Meaning
tem
RF200
Bits 0...7: Reserved (to be assigned the value "0").
RF300
Bit 0...1: Reserved (to be assigned the value "0").
Bit 2...4: Modulation depth
0: 0% (default)
1: 7%
2: 10%
3: 15%
4: 20%
5 25%
6: 30%
7: 100%
Bit 5...7: Input attenuation
0: Default (default attenuation stored in the firmware, depending on the
reader type and air interface protocol)
1: 0 dB
2: 5 dB
3: 10 dB
4: 15 dB
7: -5 dB
RF200,
Setting for the RFID mode and presence check
RF300
Bit
Description
Ident profile, Add-on instruction for Rockwell systems
Function Manual, 07/2020, C79000-G8976-C410-04