Compressor
Step
2
Remove the protection
bushing.
3
Disconnect the
compressor lead wires
and the overload
protector.
4
Remove the 2 sheets of
putty.
5
Heat up the brazed part
of the discharge side
pipe and disconnect it.
6
Heat up the brazed part
of the suction side pipe
and disconnect it.
7
Heat up the brazed part
of the accumulator and
disconnect it.
8
Remove the 2 nuts.
9
Lift up the compressor
and remove it.
24
Procedure
Protection bushing
Overload
protector
Brazed part of
the accumulator
Putty
Brazed part of
the discharge
side pipe
Compressor
U (red)
V (yellow)
W (blue)
(R22504)
Brazed part of the
suction side pipe
Putty
(R22506)
Nut
Si121561E
Points
Removal Procedure