Step
2
Pull out the 4 clamps.
3
Disconnect the
connector [S90] and the
3 terminals for power
supply.
4
Remove the 4 screws
of the terminal board
mounting plate.
Removal Procedure
Procedure
Bottom view
Clamp
[S90]
[S]
[HL1]
[HN1]
Clamp
(R22481)
(R22482)
Terminal board
mounting plate
(R22483)
Points
[S90]: thermistors
[HL1], [HN1], [S]: to terminal
board
PCBs