Vitoligno 300-C Installation/Service

Coding 2

(continued)
Boiler
Coding in the factory set condition
Flue gas residual O
partial load correction
2
0D:...
Boiler water temp delay
0F:...
Supply controller enabled
11:0
Min. set system temperature
13:1
Boiler pump minimum speed
1C:...
Do not adjust!
Boiler pump maximum speed
1D:...
Do not adjust!
Flue gas temperature minimum
3F:...
Output controller
46:...
Material controller
47:...
Increase set residual O
in
2
the flue gas by ... %.
Shutdown delay in seconds
when the max. boiler water
temperature is exceeded
(code 1, address E, boiler
group)
Supply temperature control
for the boiler is active.
If the heating circuits are
not regulated by the boiler
control unit, a minimum set
system temperature can be
selected. Setting of min.
set system temperature is
enabled.
The minimum boiler circuit
pump speed is ... % of the
maximum speed. Code only
enabled for boiler circuit
pumps with PWM signal.
Boiler circuit pump speed in
%. Code only enabled for
boiler circuit pumps with
PWM signal.
Limitation of the minimum
flue gas temperature to a
specific temperature
Do not change.
Do not change.
Possible change
0D:0
Setting range 0 to 5.0 in %
to
0D:5.0
0F:0
Setting range in sec.
to
0F:240
11:1
Supply temperature control for the
boiler is active. The boiler supply
temperature is regulated to the boiler
water temperature set in the menu
minus 3 K via the boiler valve setting.
13:0
Setting of min. set system
temperature is disabled.
1C:15
Setting range in %
to
1C:100
1D:15
Setting range in %
to
1D:100
3F:...
Setting range in °C
to
3F:...
46:...
Setting range
to
46:...
47:...
Setting range
to
A small value slows the controller
47:...
down, a large value speeds it up.
Coding