Vitoligno 300-C Installation/Service
Coding 1
(continued)
Coding in the factory set condition
Buffer type
Additional boiler: No
Charging scheme
Charging scheme:1
DHW
DHW: No
DHW circulation
DHW circulation: No
Fuel store sensor
Fuel store sensor: No
Heating circuit 1
Heating circuit 1: No
Heating circuit 2
Heating circuit 2: No
Heating circuit 3
Heating circuit 3: No
Heating circuit 4
Heating circuit 4: No
No additional boiler installed Additional boiler: Yes Additional boiler installed
Automatic charging with
vacuum module for vacuum
supply system from a pellet
silo and for discharge with
manual changeover unit
from a pellet storage room
There is no DHW heating
installed
There is no DHW circulation
connected to the control
unit of the boiler.
No level sensor installed in
the fuel store
There is no heating circuit 1
installed.
There is no heating circuit 2
installed.
There is no heating circuit 3
installed.
There is no heating circuit 4
installed.
Possible change
Charging scheme: 0
No automatic charging of the boiler
Charging scheme: 2
Automatic charging with vacuum
module and discharge screw conveyor
Charging scheme: 3
Vacuum module with external charging
Charging scheme: 4
Do not adjust!
Charging scheme: 5
Discharge screw conveyor
Charging scheme: 6
External charging
Charging scheme: 7
Screw conveyor and discharge
screw conveyor
Charging scheme: 8
Screw conveyor and external charging
DHW: On the boiler
DHW heating is connected to the
control unit of the boiler.
DHW: On the mixing
DHW heating is connected to the
valve module
extension kit.
DHW circulation: Yes The DHW circulation is connected to
the control unit of the boiler.
Fuel store sensor: Yes Level sensor installed in the fuel store
Heating circuit 1:
Heating circuit is connected to the
On the boiler
boiler control unit.
Heating circuit 1:
Heating circuit is connected to the
On the mixing valve
extension kit.
module
Heating circuit 2:
Heating circuit is connected to the
On the boiler
boiler control unit.
Heating circuit 2:
Heating circuit is connected to the
On the mixing valve
extension kit.
module
Heating circuit 3:
Heating circuit is connected to the
On the boiler
boiler control unit.
Heating circuit 3:
Heating circuit is connected to the
On the mixing valve
extension kit.
module
Heating circuit 4:
Heating circuit is connected to the
On the boiler
boiler control unit.
Heating circuit 4:
Heating circuit is connected to the
On the mixing valve
extension kit.
module
Coding
79