Power Losses Of The Components - Siemens SINAMICS S220 Equipment Manual

Booksize power units
Hide thumbs Also See for SINAMICS S220:
Table of Contents

Advertisement

8.13

Power losses of the components

The tables below provide an overview of the power loss of S220 Smart Line Modules operated
at their rated power.
The total losses of the relevant power unit (Line Module, Motor Module) are calculated from the
power loss and the corresponding electronics loss of the power unit.
The following values apply under the subsequent conditions:
• Line voltage for Line Modules 400 V
• Operating components at their rated power
Table 8-21
S220 Smart Line Modules
16 kW
24 kW
Table 8-22
S220 Smart Line Modules
16 kW
24 kW
Table 8-23
S220 Smart Line Modules
Basic Line Filter for Smart Line Modules
16 kW
24 kW
Table 8-24
S220 Smart Line Modules
Line reactors for Smart Line Modules
16 kW
24 kW
Booksize power units
Equipment Manual, 01/2022, 6SL3097-6AC30-0BP0
Power losses for power units operated at their rated power (including losses of the
electronics)
Unit
W
W
Losses of the electronics for power units
Unit
W
W
Power losses at rated operation for line filters
Unit
W
W
Power losses at rated operation for line reactors
Unit
W
W
Control cabinet design and EMC booksize
8.13 Power losses of the components
Power loss
150
250
Power loss
14.9
15.6
Power loss
12.0
22.0
Power loss
90
92
143