4.6

Line reactors

Line reactors are interfaces on the line side for the Smart Line Modules. These limit line
harmonics to permissible values. This is the reason that you must always use line reactors when
operating Smart Line Modules.
4.6.1

Overview of line reactors

The line reactors listed below must be used for operating the Line Module.
Table 4-5
Line reactors
Line reactors for S220 Smart Line Modules
16 kW C type
16 kW D type
24 kW C type
24 kW D type
4.6.2

Safety instructions for line reactors

Burns resulting from high surface temperature of the line reactor
The line reactors can become very hot. You can get seriously burnt when touching the surface.
• Mount the line reactors so that contact is not possible. If this is not possible, attach clearly
• To prevent adjacent components from suffering damage due to these high temperatures,
NOTICE
Damage to the system caused by line reactors that are not permissible
Line reactors that are not permissible can damage the Line Modules.
Line harmonics that damage/disturb other loads connected to the same line supply can also
occur.
• Only use line reactors that are listed in this Equipment Manual.
Booksize power units
Equipment Manual, 01/2022, 6SL3097-6AC30-0BP0
Overview of line reactors
CAUTION
visible and understandable warning notices at hazardous positions.
maintain a ventilation clearance of 100 mm on all sides of the line reactors.
Line connection and line-side power components
Article number
6SL3100-0EE21-6AA0
6SL5100-0EE21-6AD0
6SL5100-0EE22-4AC0
6SL5100-0EE22-4AD0
4.6 Line reactors