Honda EU30i Manual page 52

Hide thumbs Also See for EU30i:
Table of Contents

Advertisement

From page 4-4
Remove all loads from the generator. Verify that
the cooling air duct is not blocked and that the
generator is not placed near a wall.
Normal
Check the harness connecting the receptacles
and inverter unit for open or short circuit and for
proper connection.
Normal
Check the harness connecting the inverter unit
and generator for open or short and for proper
connection.
GENERATOR WIRE HARNESS
10
W
4
3
2
R
Bu
Viewed from terminal side
Normal
Check the generator (page 8-29).
Normal
Check the inverter unit (page 8-27).
Normal
Turn the ignition switch OFF and then restart the
engine. If the same symptom continues, replace
the inverter unit (page 8-7).
Abnormal
Abnormal
Abnormal
7
Abnormal
Abnormal
TROUBLESHOOTING
Remove obstruction.
Replace or repair the control wire harness
(page 8-13).
Replace or repair the generator wire harness
(page 8-10).
Replace the stator (page 8-10).
Replace the inverter unit (page 8-7).