GENERATOR/CHARGING SYSTEM
From page 8-3
Check whether the overload indicator light (red) is
ON.
Light OFF
*Equipped type only
Check the AC circuit protector (page 8-28).
Normal
Check the AC receptacle.
Normal
Remove the inverter unit (page 8-7).
Measure the resistance between the terminals of
the main coil 4P connector.
Resistance:
No.2 (R) - No.3 (W): 0.6 - 1.1Ω
No.3 (W) - No.4 (Bu): 0.6 - 1.1Ω
No.2 (R) - No.4 (Bu): 0.6 - 1.1Ω
4
3
2
Viewed from terminal side
Normal
Replace the inverter unit (page 8-7).
8-4
10
Light is ON
Disconnect the AC receptacle. Verify that the
cooling air duct is not blocked and the generator
is not placed near a wall.
Correct the above problems, and restart the
engine.
Replace the inverter unit (page 8-7).
Abnormal
Replace the AC circuit protector (page 8-13).
Abnormal
Replace the AC receptacle (page 8-13).
Abnormal
Check the harness connecting the inverter unit
and generator for an open or short circuit and for
proper connection.
10
Normal
Replace the stator (page 8-10).
Light is ON
GENERATOR WIRE HARNESS
W
4
3
2
R
B u
Viewed from terminal side
Abnormal
Replace or repair the generator wire
harness (page 8-10).