COVER SENSOR REPLACEMENT

1
Turn the printer OFF and disconnect the power supply cord.
2
Lift up the top housing cover (1) (See Figure 4-9a) to access the sensor area.
3
Remove the two screws (2) securing the cable cover (3) to the top housing cover (1).
4
Remove the screw (4) that secures the cover sensor (5) to the top housing cover (1).
3
2
5
Remove the base cover from the printer to access the main board (6) (See Figure 4-9b).
6
Remove the five screws (7) that secure the main board (6) to the printer (8).
7
Remove the main board (6) and disconnect all wiring harnesses of the defective cover-
open sensor.
8
Detach the defective sensor from the printer and route the replacement sensor in its place.
9
Connect the replacement sensor to the main board (6) and re-secure the board (6) to the
printer (8) using five screws (7).