Mechanical Specifications; Power Supply Specifications - HP Enterprise HPE Edgeline EL8000t User Manual

Converged edge system
Table of Contents

Advertisement

Table 3: Extended Edgeline specifications
Specification
Temperature range
Operating
Nonoperating
Relative humidity (noncondensing)
Operating
Non-Operating
1
All temperature ratings shown are for sea level. An altitude derating of 1.0°C per 305 m (1.8°F per 1,000 ft) to 3,048 m (10,000 ft) is
applicable. No direct sunlight allowed. Maximum rate of change is 20°C per hour (36°F per hour). No restrictions on product
configurations except for rotating hard drives. PCI cards must be rated for continuous operation with 60°C cooling air. Solid-state drives
must be rated for continuous operation with 65°C cooling air. Not rated for operation over 3,030 m (10,000 ft).

Mechanical specifications

Specification
Height
Depth
Width
Weight (approximate)
With two e910t server blades installed

Power supply specifications

Depending on installed options, the server is configured with one of the following power supplies:
1500W Hot Plug Power Supply
1500W -48VDC Hot Plug Power Supply
1
Value
0°C to 55°C (32°F to 131°F)
-40°C to 70°C (-40°F to 158°F)
8% to 90% at 28°C (82.4°F) maximum wet bulb
temperature
5% to 95% at 38.7°C (101.7°F) maximum wet bulb
temperature
Value
8.73 cm (3.44 in)
42.95 cm (16.91 in)
48.26 cm (19 in)
11.33 Kg (25 lbs)