Front View:
1.
Eight sockets for PC2-5300 Fully Buffered DIMMs
(DDR2-667)
2.
Hot-plug fans, full redundancy
3.
Systems Insight Display
4.
Quick release lever for rapid server access
5.
Support for eight Small Form Factor hot plug hard
drives bays
6.
Front LEDs (show server status) and Unit Identification
button/LED (for easy in rack server identification)
7.
Two front USB ports (2 rear USB ports, 1 internal USB
port)
8.
Intel Xeon Processor (Performance models include two
processors)
9.
Hot plug power supply, redundancy option (High
performance models include redundant power supply)
10.
Three full-size PCI-E expansion slots in standard
expansion cage (or optional mixed PCI-X/E expansion
cage). Two additional low-profile PCI-E slots embedded
on the system board. Four slots available for use; one
consumed by Smart Array controller (Base and
Performance models)
11.
Quick removal access panel
What's New
New Intel® Xeon® Dual-core 5200 series processors
DA - 12477 Worldwide QuickSpecs — Version 36 — 2/29/2008
Rear View:
1.
Torx service tool
2.
Optional pass through cable door
3.
Two Embedded NC373i Multifunction Gigabit Server
Adapters with TCP/IP Offload Engine
4.
Hot plug power supply bays, redundancy option (High
performance models include redundant power supply)
5.
Integrated Lights-Out 2 (iLO 2) Remote management
port
6.
Video Port
7.
Two USB 2.0 Ports
8.
Serial Port
9.
Keyboard Port
10.
Mouse PS/2 Port
11.
Two low-profile PCI Express x8 slots. Slot 1 is
consumed by the P400 Smart Array controller. (Base
and Performance models)
12.
Three full-size PCI Express slots in standard cage (or
optional mixed PCI-X/E expansion cage)
Page 1

Advertisement

loading

Summary of Contents for HP ProLiant HP Smart Array 256MB

  • Page 1 Front View: Eight sockets for PC2-5300 Fully Buffered DIMMs (DDR2-667) Hot-plug fans, full redundancy Systems Insight Display Quick release lever for rapid server access Support for eight Small Form Factor hot plug hard drives bays Front LEDs (show server status) and Unit Identification button/LED (for easy in rack server identification) Two front USB ports (2 rear USB ports, 1 internal USB port)
  • Page 2 Tool-less access to all system components for easy in rack serviceability Warranty: This product is covered by a global limited warranty and supported by HP Services and a worldwide network of HP Authorized Channel Partners resellers. Hardware diagnostic support and repair is available for three years from date of purchase.
  • Page 3 NOTE: For a brief, printer friendly data sheet that describes this product and informs you of the essential capabilities and specifications, please visit: http://h71028.www7.hp.com/ERC/downloads/5983-0605EN.pdf. NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information - Factory Integrated Models"...
  • Page 4 Standard (Entry Models) Standard (Base Models) Standard (Performance Models) Maximum NOTE: Memory DIMMs in systems with the Front Side Bus (FSB) running at 1333 MHz will run at 667 MHz and in systems with a FSB running at 1066 MHz or 667 MHz the memory DIMMs will run at 533 MHz.
  • Page 5 Pre-Failure Warranty (covers processors, SAS hard drives and memory) DA - 12477 Worldwide QuickSpecs — Version 36 — 2/29/2008 HP Smart Array P400/256MB Controller (RAID 0/1/1+0/5) Available upgrades: 512MB battery-backed write cache (BBWC) or standalone battery for RAID 0/1/1+0/5/6...
  • Page 6 NOTE: For additional product and licensing information about HP Insight Control Environment, visit: http://www.hp.com/go/ice. HP Insight Control management suites and most HP ProLiant Essentials include a one year of 24 x 7 HP Software Technical Support and Update Service ensuring rapid access to HP support staff and proactive delivery of software updates.
  • Page 7 For more information, visit: http://www.hp.com/go/rdp. Upgrading, replacing, or virtualizing your existing server? Effortlessly transition to new virtual or physical HP ProLiant servers or BladeSystem with automated, accurate and affordable migration of OS, application and data. SMP Universal automates the manual processes required for migrating servers between physical or virtual platforms, whether migrating to VMware or Microsoft virtual machines.
  • Page 8 SmartStart Web site at: http://www.hp.com/servers/smartstart. SmartStart version supported (minimum): SmartStart 7.51 The Insight Management Agents should be installed on all HP servers to present system instrumentation, health and configuration information into HP Systems Insight Manager and the HP System Management Homepage.
  • Page 9 327281-B21; or High Air Flow Rack Door Insert for the 7142 Rack (6-pack) - PN: 327281-B22) are required to support the HP ProLiant DL380 G5 in 7000 series racks. The DL380 G5 Cable Management Arm is not supported on 7000 series racks.
  • Page 10 HP products supported through Factory Express include a wide array of servers and storage: HP Integrity, HP ProLiant, HP ProLiant Server Blades, HP BladeSystem, HP 9000 servers as well as the MSA1000, VA7xxx, EVA, XP, rackable tape libraries and configurable network switches.
  • Page 11 NOTE: High Performance Computing (HPC) interconnect technologies are available for the DL380 under the Cluster Platform product portfolio. These high-speed interconnects are fully supported by HP when they are part of these configure to order clusters. Solutions can be defined with a lot of flexibility with the help of configuration tools. Please visit the following URL to configure HPC Clusters with InfiniBand, Gigabit Ethernet or Myrinet Interconnects: http://www.hp.com/techservers/clusters/ucp/index.html...
  • Page 12 4 GB (4 x 1 GB of PC2-5300 Fully Buffered DIMMs (DDR2-667) with Advanced ECC, mirrored and online spare memory capabilities Two Embedded NC373i Multifunction Gigabit Server Adapters HP Smart Array P400/512MB BBWC Controller (RAID 0/1/1+0/5/6) None ship standard 1.168TB (with optional hard drives) IDE DVD-ROM/CDRW combo Rack (2U), Height 3.38-inch/8.59 cm;...
  • Page 13 1 GB (2 x 512 MB) PC2-5300 Fully Buffered DIMMs (DDR2-667) with Advanced ECC, mirrored and online spare memory capabilities Two Embedded NC373i Multifunction Gigabit Server Adapters HP Smart Array E200/64MB Controller (RAID 0/1/1+0) None ship standard 1.168TB (with optional hard drives) Optional DVD, DVD/CD-RW combo, DVD+R/RW or floppy drive Rack (2U), Height 3.38-inch/8.59cm;...
  • Page 14 HP recommends the use of an HP approved configurator. Contact your local sales representative for information on CTO product offerings and requirements. NOTE: HP does not allow factory integration of options into standard models listed above. Configure-to-order servers must start with a CTO Chassis.
  • Page 15 Step 3: Choose Additional Factory Integratable Options Performance Packs The HP ProLiant DL380 G5 performance packs are necessary to configure a HP ProLiant DL380 G5 Performance Model. HP ProLiant DL380 G5 Performance model includes the latest performance technologies and enterprise class availability features pre-installed for convenience and value.
  • Page 16 Customer will receive a printed license entitlement certificate via physical shipment. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support Service NOTE: For additional License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11053_div/11053_div.html...
  • Page 17 The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support Service.
  • Page 18 Slimline Ejectable Floppy drive Optical Drives Slimline CD-RW/DVD-ROM Combo Option Kit NOTE: Included in performance models. Slimline DVD-ROM Drive (8x/24x) Option Kit HP DVD+R/RW 8X Slim Slimline CD-ROM Drive 24X DA - 12477 Worldwide QuickSpecs — Version 36 — 2/29/2008 458581-B21 462593-B21...
  • Page 19 NOTE: This option kit contains a 24" battery cable and adhesive material for installing a battery into the HP ProLiant DL380 G5 if a Smart Array P400 is integrated outside of the factory. For all solutions, please refer to the server QuickSpecs and User's Manual for detailed installation instructions.
  • Page 20 HP NC373F PCI Express Multifunction Gigabit Server Adapter HP NC373T PCI Express Multifunction Gigabit Server Adapter HP NC380T PCI Express Dual Port Multifunction Gigabit Server Adapter HP NC510F PCIe 10 Gigabit Server Adapter NOTE: A minimum of 1 gigabyte (1 GB) of server memory is required per each NC510F adapter.
  • Page 21 For recommended tape drive offerings for this ProLiant server see the following: USB Tape Drives HP StorageWorks 1U USB Rack-Mount Kit with one DAT 160 USB Tape Drive SAS Tape Drives NOTE: For the DL380 G5, HP recommends purchasing the HP SC44Ge HBA (416096-B21) for a dedicated SAS HBA for tape.
  • Page 22 (Worldwide) http://h18006.www1.hp.com/products/quickspecs/12128_div/12128_div.html (Worldwide) For an up-to-date listing of the latest O/S and software support details for HP Ultrium tape drives, please visit: http://www.hp.com/go/connect. Rack-Mount Tape Drive Enclosures HP StorageWorks 1U SCSI Rack-Mount kit NOTE: The 1U Rack-Mount Kit can support up to (2) half-height tape drives and...
  • Page 23 HP StorageWorks DAT 72x10 tape autoloader HP StorageWorks 1/8 Tape Autoloader HP StorageWorks 1/8 G2 LTO-4 Ultrium 1760 SAS Tape Autoloader HP StorageWorks 1/8 LTO-3 Ultrium 920 G2 Tape Autoloader HP StorageWorks 1/8 G2 LTO-3 Ultrium 920 SAS Autoloader HP StorageWorks 1/8 LTO-2 Ultrium 448 G2 Tape Autoloader...
  • Page 24 HP Serviceguard for Linux, A.11.18 (single license version - Red Hat EL 4&5, SUSE SLES10) HP Serviceguard for Linux and Red Hat Global File System - 1 year subscription HP Serviceguard for Linux and Red Hat Global File System - 3 years...
  • Page 25 (Worldwide) HP StorageWorks HP StorageWorks Modular Smart Array 500 Generation 2 Modular Smart Array NOTE: Please see the Modular Smart Array 500 Generation 2 QuickSpecs for 500 G2 additional information including configuration steps and additional options needed for a complete solution at: http://h18000.www1.hp.com/products/quickspecs/11956_div/11956_div.html...
  • Page 26 HP 256MB USB 2.0 Floppy Drive Key HP 5642 Rack-Unassembled HP Rack 5000 Series (Graphite Metallic) NOTE: Please see the HP Rack 5642 QuickSpecs for additional part numbers and Technical Specifications such as height, width, depth, weight, and color: http://h18000.www1.hp.com/products/quickspecs/12074_div/12074_div.html (Worldwide) NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower.
  • Page 27 HP Rack 10000 Series HP S10614 (14U) Rack Cabinet - Shock Pallet (Graphite Metallic) NOTE: xxxxxx-B22 (shock pallet) used to ship racks with equipment installed (by custom systems, VARs and Channels). NOTE: It is mandatory to use a shock pallet in order to ship racks with equipment installed.
  • Page 28 Installation and Startup for Essentials Rapid Deployment Pack, Electronic Support Plus Onsite HW support, 8am-9pm, M-F, 4hr response and Microsoft O/S SW Tech support offsite, onsite at HP's discretion, 8am-9pm, M-F 2hr response time excl. HP holidays, Electronic Support Plus 24 Onsite HW support 24x7, 4hr response and Microsoft O/S SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl.
  • Page 29 Onsite HW support 24x7, 4hr response and Red Hat ES Linux SW Tech support U8334E offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic NOTE: For more information, customer/resellers can contact: http://www.hp.com/services/carepack DA - 12477 Worldwide QuickSpecs — Version 36 — 2/29/2008...
  • Page 30 NOTE: Mirrored Memory uses mirrored banks to provide a high level of memory redundancy. Customer chooses to implement or not: User selectable via BIOS and default is off. Following are memory options available from HP: 1 GB FBD PC2-5300 2 x 512 MB Kit...
  • Page 31 Online spare memory configuration Online spare FBDIMM configuration requirements (in addition to general configuration requirements): When only bank A is being used, it must be fully populated with dual-rank FBDIMMs. If banks A and C are being used, they must be fully populated. If installed, bank A and bank C must contain FBDIMMs with identical part numbers.
  • Page 32: Drive Support

    HP ProLiant Slim CD- Only 1 available ROM x24 removable media bay HP DVD+R/RW 8X Slim Only 1 available removable media bay Hard Drives SFF SAS - Hot Plug Drives Quantity Supported 146GB 3G SAS 10K SP...
  • Page 33 Smart Array 6404/256 Controller NOTE: Optional mixed PCI-X/E cage required. External Smart Array E500/256MB Controller HP Smart Array P600/256 BBWC Controller HP Smart Array P800/512 BBWC Controller External HP Smart Array P600/256 BBWC Controller NOTE: Optional mixed PCI-X/E cage required.
  • Page 34 HP Smart Array P400/512MB Controller NOTE: Please visit: http://www.hp.com/go/connect controller firmware version and SAS cabling requirements. HP SC11Xe Host Bus Adapter HP U320e SCSI Host Bus Adapter NOTE: Only valid for MSL tape libraries. HP SC44Ge Host Bus Adapter NOTE: Please visit http://www.hp.com/go/connect minimum SAS controller firmware version and SAS cabling requirements.
  • Page 35 MSL6000 HP StorageWorks External Embedded Network Controller D2D Backup Systems D2D110 D2D120 D2D130 DA - 12477 Worldwide QuickSpecs — Version 36 — 2/29/2008 Page 35...
  • Page 36 NOTES: - To review typical system power ratings use the Active Answers Power Calculator which is available via the online tool located at url: http://h30099.www3.hp.com/configurator/calc/Power%20Calculator%20Catalog.xls To drill down to calculators: Click on: "ProLiant Servers" Click on the Server of interest. Example: DL380 G5 Click on: "Power Calculator"...
  • Page 37 3990 BTU/hr (at 240 VAC) To review typical system power ratings use the Power Calculator which is available via the online tool located at URL: http://h30099.www3.hp.com/configurator/calc/Power% 20Calculator%20Catalog.xls - Click on the system of interest. Example: DL380 G5 - Follow the instructions of the next screens.
  • Page 38 Acoustic Noise Smart Array P400 Disk Drive and Controller Enclosure Interface SAS Connectors Cache Memory Speed DDR2-533MHz with 40 or 72-bit wide bus provides up to 4.2 GB/s Server Interface SAS Speed Cache Memory Logical Drives Supported Host Memory Addressing RAID Support Smart Array E200 Disk Drive and...
  • Page 39 The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.