5.11  GDC 74A Field Calibration Utility 
Field  calibration  of  GDC  74A  units  requires  a  pressure  control  system  with 
altitude  accuracy  equal  to  or  better  than  ±5  feet  at  sea  level,  ±15  feet  at 
30,000 feet, and ±15 feet at 41,000 feet.  For calibration of the GDC 74A, the 
pressure control system must control altitude automatically. 
Purpose 
The GDC 74(X) Field Calibration utility (P/N T06‐A0156‐00) is designed to adjust the calibration 
of GDC 74A units that have failed the 14 CFR Part 43 Appendix E tests due to altitude drift. 
Limitations 
These procedures should be performed on the bench (not in the aircraft) at room 
temperature. 
The GDC 74(X) Field Calibration utility should only be used to correct errors due to 
altitude drift. 
If the drift is greater than the limits defined in the GDC 74(X) Field Calibration utility at 
any of the test points, the utility will not allow the calibration to continue and the 
GDC 74A unit must be returned to Garmin. 
If the GDC 74A unit does not pass 14 CFR Part 43 Appendix E after the calibration utility 
has been run, the GDC 74A unit should be returned to Garmin. 
Requirements 
GDC 74A unit. 
Power supply (14/28V, 500mA). 
PC with a Serial Port or serial port adapter. 
Pressure control system capable of generating the correct static pressures for 0 feet, 
11,000 feet, 30,000 feet, and 41,000 feet.  
Fabricate a cable built to interface a GDC 74A to a PC Serial Port (see Figure 5‐10). The 
cable is not available from Garmin. 
 
Cirrus Perspective™ Line Maintenance Manual
190-00920-00
NOTE 
Figure 5‐10.  GDC 74A ‐ PC Interface Cable 
 
Page 5-75
Rev. E