5.8.9   GIA Configuration Alerts 
 
Message 
GIA1 CONFIG – GIA1 
configuration error.  Config 
service req'd. 
GIA2 CONFIG – GIA2 
configuration error.  Config 
service req'd. 
GIA1 CONFIG – GIA1 audio 
config error.  Config service 
req'd. 
GIA2 CONFIG – GIA2 audio 
config error.  Config service 
req'd. 
HW MISMATCH – GIA 
hardware mismatch.  GIA1 
communication halted. 
HW MISMATCH – GIA 
hardware mismatch.  GIA2 
communication halted. 
MANIFEST – GIA1 software 
mismatch.  Communication 
Halted. 
MANIFEST – GIA2 software 
mismatch.  Communication 
Halted. 
GIA1 SERVICE – GIA1 needs 
service.  Return unit for 
repair. 
GIA2 SERVICE – GIA1 needs 
service.  Return unit for 
repair. 
 
Page 5-70
Rev. E
Cause 
The system has detected a 
GIA configuration 
mismatch. 
The system has detected a 
GIA audio configuration 
mismatch. 
The system has detected a 
non‐WAAS GIA 63. 
The system has detected 
an incorrect software 
version loaded in GIA 1.   
The system has detected 
an incorrect software 
version loaded in GIA 2.   
The system has detected a 
failure in GIA1. 
The system has detected a 
failure in GIA2. 
Solutions 
See Section 7 for GIA configuration 
instructions. 
If problem persists, check config 
module harness for faults and 
replace if necessary. 
See Section 7 for GIA configuration 
instructions. 
If problem persists, check config 
module harness for faults and 
replace if necessary. 
Replace GIA with a WAAS unit. 
 
Load correct software version. 
Replace GIA1. 
Replace GIA2. 