Gmu 44 Related Alerts - Garmin CIRRUS PERSPECTIVE SR20 Line Maintenance Manual

Hide thumbs Also See for CIRRUS PERSPECTIVE SR20:
Table of Contents

Advertisement

____________________________________________________________________
GRS 77 Related Alerts (continued) 
 
Message 
MANIFEST – AHRS1 software 
mismatch.  Communication 
Halted. 
MANIFEST – AHRS2 software 
mismatch.  Communication 
Halted. 
AHRS MAG DB – AHRS 
magnetic model database 
version mismatch. 
 
5.9.3  GMU 44 Related Alerts 
 
Message 
MANIFEST – GMU1 
software mismatch.  
Communication Halted. 
MANIFEST – GMU2 
software mismatch.  
Communication Halted. 
HDG FAULT – AHRS1 
magnetometer fault has 
occurred. 
HDG FAULT – AHRS2 
magnetometer fault has 
occurred. 
 
Cirrus Perspective™ Line Maintenance Manual
190-00920-00
Cause 
The system has detected 
an incorrect software 
version loaded in GRS 77 
#1.   
The system has detected 
an incorrect software 
version loaded in GRS 77 
#2.   
The system has detected a 
magnetic model database 
version mismatch. 
Cause 
The system has detected an 
incorrect software version 
loaded in GMU 44 #1. 
The system has detected an 
incorrect software version 
loaded in GMU 44 #2. 
A fault has occurred in GMU 
44 #1. 
A fault has occurred in GMU 
44 #2. 
Solutions 
Load correct software version in the 
GRS77. 
 
Reference Garmin SB 0533 for 
update instructions. 
Solutions 
Load correct software version in the 
GMU44. 
Check GMU 44/GRS 77 interconnect 
for faults 
Replace GMU 44 #1 
If problem persists, replace  
GRS 77 #1 
Check GMU 44/GRS 77 interconnect 
for faults. 
Replace GMU 44 #2 
If problem persists, replace  
GRS 77 #2 
Page 5-73
Rev. E

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cirrus perspective sr22Cirrus perspective sr22tn

Table of Contents