Initial System Setup

Initial System Setup
1. Check the shipment for accuracy. Ensure you have
received everything you ordered. See Component
Identification, page 15.
2. Check for loose fittings and fasteners.
3. Install optional solvent flush pump kit 262393, if
ordered. See manual 310863 for instructions.
4. Mount and connect optional heaters, if ordered. See
the heater adapter kit manual 406861 and the
heater manual 309524 for instructions.
5. Install desiccant kits if using polyurethane isocya-
nates in hoppers. See manual 406739 for instruc-
tions.
6. Install circulation and return tube kits if you are feed-
ing material from drums or remote hoppers. See
manual 309852 if you are feeding urethane mate-
rial.
7. Install hopper or hose heat circulation kit 24M224, if
ordered. See 313259 for instructions.
NOTE: Supply return lines must be used.
8. Connect the feed pumps, fluid strainers, and air
hoses as necessary. If your system does not use
hoppers, then see manual 312769.
9. XP Units: Connect the air supply line. See Connect
Air Supply, page 23.
XP-h Units: Connect the hydraulic lines. See
334914 for instructions.
10. Connect the fluid hose assembly, including the
static mixers, whip hose and gun. See Pressure
Relief Procedure, page 24.
11. Flush test oil from system as needed. See Empty
and Flush Entire System (new system or end of
job), page 31.