Prime Empty System; Prime A And B Fluids - Graco XP35 Instructions Manual

Proportioners
Hide thumbs Also See for XP35:
Table of Contents

Advertisement

Prime Empty System

Prime A and B Fluids

Wear gloves when using flush solvents and/or if the
fluid temperature exceeds 110°F (43°C).
NOTE: The equipment is tested with mineral oil at
the factory. If necessary, flush out the oil with a
compatible solvent before spraying. See Empty and
Flush Entire System (new system or end of job),
page 31.
Do not install the gun spray tip yet. To avoid splash-
ing, use the lowest pressure possible to prime.
1. Condition the materials prior to adding to the hop-
pers (J). Ensure that the resin materials are thor-
oughly mixed, homogenous, and pourable prior to
adding to the hopper. Stir the hardeners back into
suspension prior to adding material to hopper.
2. Fill the A and B reservoirs with proper materials. Fill
the A side (blue) with major volume of material; fill
the B side (green) with minor volume of material
(unless 1:1 mix ratio).
3. Move the recirculation lines (U) to empty containers.
3A0420V
4. Close the dual shutoff handle (AE) and open the cir-
5. XP Systems only: Open the main air shutoff valve
6. XP-h Systems only: Set pump valve on. Then turn
J
7. Dispense fluid into the containers until clean fluid
8. Decrease air pressure. Close the main air shutoff
9. Move the recirculation lines (U) back to the correct
10. If using heaters, heat fluid throughout system before
U
culation handle (AC).
AC
AE
(CA). Then slowly open the air regulator (CB).
CB
CA
down the pressure control knob.
ti7108a
comes out of the A and B recirculation lines.
valve (CA).
hopper (J).
spraying. See Recirculate Prior to Spraying or
Re-Prime After a Pump Runs Dry, page 27.
Prime Empty System
r_571101_3A0420A_9a-2
ti7111b
25