Graco XP35 Instructions Manual page 42

Proportioners
Hide thumbs Also See for XP35:
Table of Contents

Advertisement

Repair
7. Slide handle (311) onto valve stem and rotate
approximately 90° until you feel it fully lock against
the valve seat. Repeat for opposite side.
8. Remove handle then place handle (311) on valve
stem (302) at the vertical, or near vertical, position.
9. Apply blue threadlock on the nut (304) threads and
tighten the handle against the spring (320) and
clip (318). Torque to 70-80 in-lb (7.9-9 N•m).
10. Place the rod (312) and the second handle (311) on
second valve stem aligned with the opposite handle.
11. Repeat step 9.
Fluid Circulation Manifold Replacement Guide
Circulation
Relief
Manifold (35)
Valve (302)
Part No.
Part No.
262784
262808
262783
262809
262806
262520
NOTE: Original XP70 valves did not include a silver valve sleeve. When replacing these original valves, replace with
the current valves that have the silver valve sleeve.
42
Colored Valve Sleeve
ti19168a
Target Opening
Valve Sleeve
Color
Purple
Gold
Silver
12. Install two screws (313) in handles (311).
13. Check operation of the handle and valves.
14. Operate the handle in and out of the spray and cir-
culate positions.
15. Check for clearance with fittings.
NOTE:
Both valves should settle firmly into the spray
position inward against the seats in the valve.
Both valve stems should rotate out to their most
extended positions when the handle is pulled
down to the circulate position.
Pressure
psi (MPa, bar)
5300 (37, 365)
7100 (49, 490)
284202, 284252, 284302, 284402
9250 (64, 638)
284203, 284253, 284303, 284403
ti19169a
Use with:
All XP35 models,
XP-h models 284101, 284251,
284201, 284301, 284401
All XP50 models,
XP-h models 284102,
All XP70 models,
XP-h models 284103,
3A0420V

Hide quick links:

Advertisement

Table of Contents
loading