Technical Data - Graco XP35 Instructions Manual

Proportioners
Hide thumbs Also See for XP35:
Table of Contents

Advertisement

Technical Data

XP Proportioners
Maximum Fluid Working Pressure
Maximum Air/Hydraulic Oil Working Pressure
Combined Fluid Output (cc/cycle)
Pressure Ratio
Fluid Flow at 40 cpm
Hydraulic Fluid Consumption (XP-h models only)
Air inlet size
Maximum air pressure supply to the system
Fluid pump inlets without hoppers
Fluid gauge manifold outlets
Fluid mix manifold inlets
Mix manifold material outlet
Maximum feed pressure from remote source
Sound pressure
Sound power
Maximum Storage Time
Maximum Lifetime
Power Efficiency Factor (XP70)
Air consumption per 1 gallon (3.78 l) of flow
XP70
XP50
XP35
Filtration:
Air inlet filtration
XP pump outlets
XTR Spray Gun
Fluid Viscosity Range:
Gravity feed with 7 gallon (26 liter) hoppers
Pressure feed
Environmental Rating (Indoor/outdoor)
Hazardous Areas
Ambient Temperature Range:
Operating
Storage
Maximum Fluid Temperature
Wetted materials:
Housings and manifolds
Miscellaneous parts
Pump packings
Flush pump suction tube
Hoses
3A0420V
U.S.
See Models section beginning on page 11.
See Models section beginning on page 11.
See Models section beginning on page 11.
See Models section beginning on page 11.
See Models section beginning on page 11.
0.2 gallons per cycle
3/4 npsm(f)
175 psi
1-1/4 in. npsm(m)
1/2 in. npt(f)
1/2 in. npt(f) ball valves
1/2 in. npt(f)
250 psi
86 dBA at 100 psi (7 bar, 0.7 MPa)
98 dBA at 100 psi (7 bar, 0.7 MPa)
5 years (To maintain original performance, replace soft
seals after 5 years of inactivity.)
Indefinite with recommended maintenance and periodic
rebuilds for critical parts.
75 cu. ft compressed air/1 gallon sprayed material at 100 psi
3
2.12 m
compressed air/1 liter sprayed material at 7 bar
(0.7 MPa)
75 scfm at 100 psi/gpm (2.12 m
60 scfm at 100 psi/gpm (1.7 m
50 scfm at 100 psi/gpm (1.42 m
40-micron filter/separator included
30 mesh
60 mesh
200 to 20,000 cps (pourable)
Any viscosity that will not require feed pressure more than
15% of outlet pressure
EX II 2 G c IIA T2
NOTE: XP-h pump packages (284xxx) are not Ex rated.
40-130°F
30-160°F
160°F
Carbon steel with electroless nickel plating
Plated carbon steel, stainless steels, carbide, acetal, UHM-
WPE, nylon, PTFE solvent resistant plastics
Carbon filled PTFE, proprietary UHMWPE
Aluminum
Nylon core
Technical Data
Metric
0.76 liters per cycle
12 bar, 1 MPa
17 bar, 1.7 MPa
3
/min at 7 bar, 0.7 MPa)
3
/min at 7 bar, 0.7 MPa)
3
/min at 7 bar, 0.7 MPa)
4-54°C
-1-71°C
71°C
63