3.3.3 WAN/PoE+ Power Supply and Backhaul Configuration:

Connect the cables for the WAN/PoE+ power supply and backhaul configuration, as shown in
the following steps. Refer to Figure 3-8.
1. Connect the AC power supply to the LAN switch and the other end to a power outlet.
2. Connect the Ethernet cable to the WAN/PoE+ port on the eNB.
3. Connect the other end of the Ethernet cable to the PoE+ port on the LAN switch.
4. Connect another Ethernet cable to the Ethernet port on the LAN switch.
5. Connect the other end of the Ethernet cable to the Ethernet port on the Ethernet
switch.

Figure 3-8: WAN/PoE+ and Power Supply Backhaul Configuration

3.4 Power on to Check LED Status

After the Neutrino-430 is powered on, check that the LED indicators are lighting as expected:
Power is steady green, cell activated is slow flash green, and there are no alarms (Figure 3-9)
per previous Table 2-2.

Figure 3-9: Check LEDs