Msu-750, Master Setup Unit; Operation Panel - Sony BVP-E10 Series Product Information Manual

Hide thumbs Also See for BVP-E10 Series:
Table of Contents

Advertisement

7-11.MSU-750, Master Setup Unit

7-11-1Operation Panel

8 Camera/CCU function ON/OFF
buttons
9 Scene file control block
q; Monitor output select buttons
qa Camera select block
a (1) ALL button
a
a
a
Press the button so it starts flashing to activate the 11
buttons located at the right (from CAM PW to AUTO
SETUP) for all the connected cameras of the same
group.
b CAM PW (camera power) button
b
b
b
Press and light up this button to turn the power supply
to the video camera ON. (The button promptly flashes
until the camera becomes ready for transmission.)
When you press this button again, it starts flashing and
the power supply to the camera is turned off.
c
c VF PW (viewfinder power) button
c
c
BVP-900/P cameras only: Press and light up this
button to turn the power supply to the viewfinder ON.
When you press the button again, it goes dark and the
power supply is turned off.
1 ALL button
2 CAM PW button
3 VF PW button
4 Signal output select buttons
5 CLOSE button
6 STANDARD button
AUTO
ALL
CAM PW
VF PW
TEST
BARS
CLOSE STANDARD
HUE
5600K AUTO
SKIN
CHARACTER
ECS/SHUTTER
KNEE
DETAIL
ACCESS
1
2
3
4
5
SCENE FILES
STORE
R
G
B
SEQ
ENC
WF
PIX
MONITOR
MODE
MULTI
CARD
CONFIG
MAINTENANCE
FILE
PAINT
FUNCTION
PANEL
PARA EXPAND
ACTIVE
MULTI
TALLY
0 7
0 8
0 9
1 0
1 1
1 2
MULTI
TALLY
0 1
0 2
0 3
0 4
0 5
0 6
MASTER BLACK
qk MASTER BLACK control block
d Signal output select buttons
d
d
d
Press and light up one of these buttons to activate the
test signal generator of the video camera and send the
respective signals.
TEST: To send a signal to test the video circuits
BARS: To send a colour bar signal
Note
The BARS button takes priority to the TEST button. If
the BARS button is lit, press the button to turn it dark
before pressing the TEST button.
e CLOSE (iris close) button
e
e
e
Press and light the button to close the iris. Press again
to release the close mode.
f
f
f
f STANDARD button
When you press this button, the video camera is
initialized to its standard state and the button remains
illuminated for several seconds. If you press the button
7 AUTO SETUP block
AUTO SETUP
LEVEL
START/
WHITE BLACK
BREAK
qs Display window block
MASTER
ND
CC
GAMMA
GAIN
FILTER
qd IC card insertion block
IC MEMORY CARD
qf Menu operation block
qg CALL button
CALL
IRIS/MB
qh IRIS/MB ACTIVE button
ACTIVE
EXT
AUTO
qj Iris control block
IRIS
MASTER SETUP UNIT
ql Camera number/tally indication window