Henny Penny FlexFusion FGG-615 Operating Manual page 61

Gas gold combi
Hide thumbs Also See for FlexFusion FGG-615:
Table of Contents

Advertisement

Error
Error no.
group
07
11
07
12
07
13
07
14
07
16
07
17
07
18
07
40
07
41
07
42
07
43
07
60
07
61
07
62
07
70
07
72
08
1
08
2
08
3
08
4 / 5 / 6
Failure
Top cooking chamber
sensor defective
Bottom cooking chamber
sensor defective
Emergency operation due to
defective top cooking zone
sensor
Emergency operation due to
defective bottom cooking
zone sensor
Vapour sensor defective
Moisture sensor defective
Excess temperature in the
cooking chamber
Internal core temperature
sensor defective
External core temperature
sensor defective
Internal core temperature
sensor defective
Sous-Vide core temperature
sensor defective
Fan defective or
temperature limiter triggered
Top fan defective or
temperature limiter is
triggered
Bottom fan defective or
temperature limiter is
triggered
Water pressure too low
Water pressure fault with
WaveClean
No gas
No gas at the top
No gas at the bottom
No flame / at top / at bottom
Operating instructions
Possible causes
• Sensor failure
• Sensor failure
• Sensor failure
• Sensor failure
• Sensor failure
• Sensor failure
• Sensor failure
• Sensor failure
• Sensor failure
• Sensor failure
• Water valve closed
• Too many water con-
sumers opened at the
same time
• Water pressure too low
Troubleshooting
Remedy
• The second cooking zone
sensor is used as a sub-
stitute sensor
• Contact Customer service
• Contact Customer service
• Contact Customer service
• Contact Customer service
• Switches over to internal
4-point core temperature
sensor
• Contact Customer service
• Switches over to external
4-point core temperature
sensor
• Contact Customer service
• Switches over to internal
core temperature sensor
• Contact Customer service
• Contact Customer service
• Contact Customer service
• Contact Customer service
• Open the water valve
• Close the other water con-
sumers
• Contact Customer service
• If there is the correct wa-
ter pressure, WaveClean
starts automatically
• Open the gas supply
• Switch on the condensa-
tion hood if necessary
• Contact Customer service
• Contact Customer service
61

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents