RSAU0025F0 AHU

Model Number ......................................................... TCCA
Water Connection Size ............................. 2.5 in Victaulic
Ambient Operating Conditions
Supply Motor............................................................ 20 hp
Fused Disconnect .........................................................Yes
Number of Electrical Circuits ..........................................1
Discharge Configuration.................................. Horizontal
Flex Duct Connection Size ............................ 19 in round
Number of Discharge Air Connections ..........................2
Max Discharge Static Pressure ......................5.82 in ESP
2
Filter Rack (Qty and size)
Nominal Air Flow (cfm) ..........................................10,000
3
Min/Max Air Flow (cfm)
Selection is required for actual AHU performance.
1
For ambient conditions below 40°F, glycol is recommended.
2
Unit provided with standard 2 in filters. Filter rack will accept up to 95%
efficient MERV 14 filters.
3
Min/Max airflow is dependent upon external static pressure requirement.
Contact Rental Services for specific airflow and static pressure information.
Electrical Data
Voltage ........................................................ 460V 3-phase
Frequency ..................................................................60 Hz
Lug(s) can accept wire up to ..................... #3 AWG wire
Minimum Circuit Ampacity (MCA) ................ 42.5 amps
Maximum Overcurrent Protection (MOP) ......... 60 amps
Provided with 50 ft of 4 conductor, 8 awg multicable
For additional electrical information, contact Trane Rental Services.
CHS-SVX02C-EN
1
........................14–104°F
... (4) 24 in x 24 in, (2) 24 in x 12 in
..............................5,500/11,250
Performance Data
CFM
Air Pressure Drop through Unit (in H
Entering Air DB/WB Temp (°F)
Leaving Air DB/WB Temp (°F)
GPM
Entering Water Temp (°F)
Leaving Water Temp (°F)
Coil Water Pressure Drop (ft H
Sensible Capacity (MBH)
Total Capacity (MBH)
Coil Face Area (sq ft)
Coil Rows
Water Flow Rates
Flow (GPM)
Pressure Drop (ft H
0)
2
Maximum water side pressure is 150 psi (2.31' H
Dimensions and Weights
Length
Width
Height
Weight
Width includes permanently mounted piping manifold.
Lifting Device: Fork Lift or Crane
10,000
0)
2.98
2
84/77
50/49.9
150
44
56
0)
4.55
2
379.73
909.85
20.43
10
Minimum
Maximum
70
340
1.38
19.57
0 = 1 psi)
2
16 ft 1 in
7 ft 4 in
7 ft 6 in
6,000 lb
7