Rsau0062F2 Ahu - Trane TCCA Accompaniment To The Installation, Operation And Maintenance Manual

Table of Contents

Advertisement

RSAU0062F2 AHU

Model Number ..........................................................TCPA
Water Connection Size ................................ 4 in Victaulic
Ambient Operating Conditions
Supply Motor(s) .................................................. (2) 30 hp
OCP Device ................................................Circuit Breaker
Number of Electrical Circuits ..........................................1
Discharge Configuration.................................. Horizontal
Flex Duct Connection Size............................. 19 in round
Number of Discharge Air Connections ..........................6
Max Discharge Static Pressure ........................6.0 in ESP
Number of Return Air Connectors..................................6
2
Filter Rack (Qty. and size)
Nominal Air Flow (cfm) ..........................................25,000
3
Min/Max Air Flow (cfm)
Selection is required for actual AHU performance.
1
For ambient conditions below 40°F, glycol is recommended.
2
Unit provided with standard 2 in filters. Filter rack will accept up to 95% efficient
MERV 14 filters.
3
Min/Max airflow is dependent upon external static pressure requirement. Con-
tact Rental Services for specific airflow and static pressure information.
Electrical Data
Voltage ........................................................ 460V 3-phase
Frequency ..................................................................60 Hz
Electrical Connection Type......................Cam Type Only
SCCR .............................................................................65K
Minimum Circuit Ampacity (MCA) ............ 101.25 amps
Maximum Overcurrent Protection (MOP) ....... 125 amps
For additional electrical information, contact Trane Rental Services.
28
1
........................14–104°F
...(12) 24 in x 24 in, (4) 24 in x 12 in
..............................5,600/26,000
Performance Data
CFM
Air Pressure Drop through Unit (in H
Cooling Coil
Entering Air DB/WB Temp (°F)
Leaving Air DB/WB Temp (°F)
GPM
Entering Water Temp (°F)
Leaving Water Temp (°F)
Coil Water Pressure Drop (ft H
Sensible Capacity (MBH)
Total Capacity (MBH)
Coil Face Area (sq ft)
Coil Rows
Water Flow Rates
CW Coil Flow (GPM)
CW Coil Pressure Drop (ft H
Dimensions and Weights
Length
Width
Height
Weight
Lifting Device: Fork Lift or Crane
25,000
0)
3.28
2
84/77
49.6/49.6
374.92
44
56
0)
24.56
2
931.3
2254.7
49.6
10
Minimum
Maximum
60
555
0)
0.86
50.97
2
19 ft 0 in
8 ft 6 in
9 ft 9 in
12,100 lbs
CHS-SVX02C-EN