RSAU0062F1 AHU

Model Number ..........................................................TCCB
Water Connection Size ................................ 4 in Victaulic
Ambient Operating Conditions
Supply Motor............................................................ 50 Hp
Fused Disconnect ......................................................... Yes
Number of Electrical Circuits .......................................... 1
Discharge Configuration...................................Horizontal
Flex Duct Connection Size..............................19 in round
Number of Discharge Air Connections .......................... 4
Max Discharge Static Pressure ...................... 5.72 in ESP
Number of Return Air Connections ................................ 5
2
Filter Rack (Qty and size)
.... (12) 24 in x 24 in, (4) 12 in x 24 in
Nominal Air Flow (cfm) .......................................... 25,000
3
Min/Max Air Flow (cfm)
Selection is required for actual AHU performance.
1
For ambient conditions below 40°F, glycol is recommended.
2
Unit provided with standard 2 in filters. Filter rack will accept up to 95% efficient
MERV 14 filters.
3
Min/Max airflow is dependent upon external static pressure requirement. Con-
tact Rental Services for specific airflow and static pressure information.
Electrical Data
Voltage ......................................................... 460V 3-phase
Frequency ..................................................................60 Hz
Lug(s) can accept wire up to .............................250 MCM
Minimum Circuit Ampacity (MCA) .................... 83 amps
Maximum Overcurrent Protection (MOP) ....... 125 amps
For additional electrical information contact Trane Rental Services.
Provided with 50 ft of 4 conductor, 4 awg multicable
CHS-SVX02C-EN
1
...................... 14 - 104°F
............................ 11,000/27,500
Performance Data
CFM
Air Pressure Drop through Unit (in H
Cooling Coil
Entering Air DB/WB Temp (°F)
Leaving Air DB/WB Temp (°F)
GPM
Entering Water Temp (°F)
Leaving Water Temp (°F)
Coil Water Pressure Drop (ft H
Sensible Capacity (MBH)
Total Capacity (MBH)
Coil Face Area (sqft)
Coil Rows
Heating Coil
Entering Air DB/WB Temp (°F)
Leaving Air DB/WB Temp (°F)
GPM
Entering Water Temp (°F)
Leaving Water Temp (°F)
Coil Water Pressure Drop (ft H
Total Capacity (MBH)
Coil Face Area (sq ft)
Coil Rows
Water Flow Rates
CW Coil Flow (GPM)
CW Coil Pressure Drop (ft H
HW Coil Flow (GPM)
HW Coil Pressure Drop (ft H
Dimensions and Weights
Length
4
Width
Height
Weight
4
Width does not include field installed piping manifold.
Lifting Device: Fork Lift or Crane
25,000
0)
3.28
2
84/77
50/49.9
378
44
56
0)
11.78
2
949.3
2274.6
50
10
45
78
89
180
160
0)
3.56
2
894.72
40.6
1
Minimum
Maximum
125
500
0)
1.88
19.48
2
30
200
0)
0.55
21.77
2
22 ft 9 in
8 ft 6 in
9 ft 10.5 in
15,100 lbs
25