Circuit Requirements for 220V
These machines are prewired to operate on a power supply circuit that has a verified ground and meets the
following requirements:
Model Number
Circuit Requirements For 220V Operation:
Nominal Voltage
Cycle
Phase
Power Supply Circuit
Plug/Receptacle
Power Cord
Circuit Requirements for 110V
Models G0513, G0513A40, and G0513X2 can be converted to operate on a power supply circuit that has
a verified ground and meets the requirements listed below. (Refer to Voltage Conversion instructions for
details.)
Model Number
Circuit Requirements For 110V Operation:
Nominal Voltage
Cycle
Phase
Power Supply Circuit
Plug/Receptacle
Power Cord
Grounding Requirements
This machine MUST be grounded. In the event
of certain malfunctions or breakdowns, grounding
reduces the risk of electric shock by providing a
path of least resistance for electric current.
Grounding Requirements for 220V: The plug
specified under "Circuit Requirements for 220V
Operation" on this page has a grounding pin that
must be attached to the equipment-grounding
wire inside the specified power cord. The plug
must only be inserted into a matching recep-
tacle (see Figure 5) that is properly installed and
grounded in accordance with all local codes and
ordinances.
G0513 Series Bandsaws (Mfd. Since 08/22)
G0513, G0513A40, G0513X2
"S"-Type, 3-Wire, 14 AWG, 300 VAC
G0513, G0513A40, G0513X2
110V, 115V, 120V
60 Hz
Single-Phase
30 Amps
NEMA L5-30
"S"-Type, 3-Wire, 12 AWG, 300 VAC
208V, 220V, 230V, 240V
60 Hz
Single-Phase
15 Amps
NEMA 6-15
GROUNDED
6-15 RECEPTACLE
Current Carrying Prongs
6-15 PLUG
Grounding Pin
Figure 5. Typical 6-15 plug and receptacle.
G0513X2BF
G0513X2BF
N/A
-11-