Agilent Technologies HDMP-3001 Datasheet page 85

Ethernet over sonet mapper ic device specification
Table of Contents

Advertisement

ADDR = 0x194-0x197: TX_ER Error Counter
ADDR
Bit name
0x194
0x195
0x196
0x197
R/W
Value
after
reset
TX_ER_ERR is the TX_ER Error counter. It is non-resetable except that a hard or soft reset will clear it.
After reaching its max value the counter starts over from zero again.
This counter is incremented by frames where TX_ER was detected active while the frame was being
received but did not cause a FIFO error.
ADDR = 0x198-0x19B: TX FIFO Overflow Error
ADDR
Bit name
0x198
0x199
0x19A
0x19B
R/W
Value
after
reset
TX_FIFO_OF_ERR is the TX_FIFO Overflow Error counter. It is non-resetable except that a hard or soft
reset will clear it. After reaching its max value the counter starts over from zero again.
This counter is incremented each time there is a FIFO overflow and hence a frame is discarded.
85
Bit 7
Bit 6
TX_ER_ERR [7:0]
TX_ER_ERR [15:8]
TX_ER_ERR [23:16]
Fixed 0
RO
0
Bit 7
Bit 6
TX_FIFO_OF_ERR [7:0]
TX_FIFO_OF_ERR [15:8]
Fixed 0
Fixed 0
RO
0
Bit 5
Bit 4
Bit 3
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Bit 2
Bit 1
Bit 0