ISO: VENTING TO FRONT
90 50
140
60 – 200
PROFILE: SEPARATE HOUSING
All dimensions are in mm
10
Rear edge
of cutout
60 – 200
PROFILE: SHELVING
VENTING PREPARATION
A toe kick height of at least 60mm is required.
z
Front facing venting is achievable in both island and wall installations providing adequate
z
airflow is present at the outlet location.
Venting to the front through the same cabinet can be achieved using the supplied ducting
z
components. A maximum venting height of 899mm* can be achieved alongside a maximum
venting depth of 591mm. These distances can be extended by using accessory kit
D1-C-218-55.
Venting to the front through the adjacent cabinet can be achieved through the use of
z
accessory kits D1-C-218-55 and E90-218-55.
A space of 140mm is required at the rear of the cabinetry to house the ducting components.
z
Alternately, if vertical ducting is to pass through any shelving, ensure a cutout of 232mm x
100mm has been created in all shelves.
Access through the base of the cabinetry to connect ducting components is recommended.
z
Every 3m or additional bend drops extraction performance by 2%.
z
A toe kick height of at least 60mm is required.
z
Rear facing venting is only achievable in island installations providing adequate airflow is
z
present at the outlet location.
Venting to the rear through the same cabinet can be achieved using the supplied ducting
z
components. A maximum venting height of 899mm* can be achieved alongside a maximum
venting depth of 591mm. These distances can be extended by using accessory kit
D1-C-218-55.
Venting to the rear through the adjacent cabinet can be achieved through the use of
z
accessory kits D1-C-218-55 and E90-218-55.
A space of 140mm is required at the rear of the cabinetry to house the ducting
z
components**. Alternately, if vertical ducting is to pass through any shelving, ensure a
cutout of 232mm x 100mm has been created in all shelves.
Rear edge
of cutout
Access through the base of the cabinetry to connect ducting components is recommended.
z
Every 3m or additional bend drops extraction performance by 2%.
z
65 35
A toe kick height of at least 60mm is required.
z
Venting to the side is achievable in both island and wall installations providing adequate
z
airflow is present at the outlet location.
100
Venting to the side can be achieved through the use of accessory kits D1-C-218-55 and
z
E90-218-55 and can be configured via the front or the rear.
A space of 140mm is required at the rear of the cabinetry to house the ducting
z
components**. Alternately, if vertical ducting is to pass through any shelving, ensure a
cutout of 232mm x 100mm has been created in all shelves.
Access through the base of the cabinetry to connect ducting components is recommended.
z
Every 3m or additional bend drops extraction performance by 2%.
z
*From underside of glass to base of outlet | **When vertical ducting and elbow housed within cabinetry only
VENTING TO THE FRONT
VENTING TO THE REAR
VENTING TO THE SIDE