DOWNDRAFT INDUCTION COOKTOP
MINIMAL
CID834RDTB4
INSTALLATION GUIDE
BI

Advertisement

Table of Contents
loading

Summary of Contents for Fisher & Paykel CID834RDTB4

  • Page 1 DOWNDRAFT INDUCTION COOKTOP MINIMAL CID834RDTB4 INSTALLATION GUIDE...
  • Page 3 Safety and warnings READ AND SAVE THIS GUIDE WARNING! General Use Electric Shock Hazard Read these instructions carefully before installing this product. Failure to follow this advice may result in Save these instructions for the local electrical inspector’s use. Installation must comply with your local building and local electricity regulations. electric shock or death.
  • Page 4: Installation Considerations

    INSTALLATION CONSIDERATIONS BEFORE INSTALLATION DURING INSTALLATION Please ensure the following: Please ensure the following: A suitable disconnection switch is incorporated in the permanent wiring, mounted and Flush mounting or sealing this appliance into the bench with silicone or glue may make positioned to comply with the local wiring rules and regulations.
  • Page 5: Tools And Components

    TOOLS AND COMPONENTS PARTS SUPPLIED COMPONENTS REQUIRED Keep all packing materials until the unit has been inspected. Inspect the product to ensure there is no shipping damage. If any damage is detected contact the dealer or retailer you bought the product from to report the damage. Fisher &...
  • Page 6: Product Dimensions

    PRODUCT DIMENSIONS PRODUCT DIMENSIONS A Overall height of cooktop B Overall width of cooktop C Overall depth of cooktop* D Depth of cooktop surface E Height of chassis F Width of chassis G Depth of chassis H Depth of front overhang of cooktop glass** I Depth of rear overhang of cooktop glass** PLAN ISOMETRIC...
  • Page 7: Accessory Dimensions

    ACCESSORY DIMENSIONS HORIZONTAL ELBOW DUCTING ACCESSORY DIMENSIONS A Overall height of horizontal elbow B Overall width of horizontal elbow C Overall depth of horizontal elbow D Overall height of ducting E Overall width of ducting F Overall depth of ducting 1000 G Overall height of connector H Overall width of connector...
  • Page 8: Flush Installation

    CUTOUT PROUD INSTALLATION FLUSH INSTALLATION PLAN PLAN FRONT FRONT CUTOUT DIMENSIONS CUTOUT DIMENSIONS A Overall width of cutout A Overall width of routered recess B Overall depth of cutout B Overall depth of routered recess C Minimum depth at rear C Overall width of cutout D Corner radius of cutout max 10...
  • Page 9: Clearance Dimensions

    CLEARANCES CLEARANCE DIMENSIONS A Minimum clearance from top of cook surface to non-combustible surface B Minimum clearance below countertop** C Minimum clearance from side of cutout to nearest adjacent combustible surface D Minimum clearance from countertop to overhead cabinet (not directly above cooktop) E Maximum depth of overhead cabinetry F Minimum distance between overhead cabinets (centred above cooktop)
  • Page 10 VENTING PREPARATION VENTING TO THE FRONT A toe kick height of at least 60mm is required. Front facing venting is achievable in both island and wall installations providing adequate airflow is present at the outlet location. Venting to the front through the same cabinet can be achieved using the supplied ducting components.
  • Page 11 ELECTRICAL CONNECTION CONNECTION LOCATION SINGLE-PHASE CONNECTION Before connecting the cooktop to the mains power supply check that: 220-240V~ Ensure cable is tightened with screw. The domestic wiring system is suitable for the power drawn by the cooktop. You may have to remove the screw The voltage corresponds to the value given in the rating plate.
  • Page 12 INSTALL DUCTING 333mm Prepare the toe kick panel to the illustrated specifications. Fit the outlet to the ducting and 13mm 33mm We recommend sealing the panel 60mm - tape to secure. 200mm with a waterproof barrier to prevent any moisture damage. max panel thickness: 16mm Align the outlet to the toe kick panel and adjust the height...
  • Page 13 INSTALL COOKTOP – PROUD Optional 50mm extender block Slot the two filter housing components together. If using the supplied 50mm extension blocks*, Turn the cooktop upside down add between the two filter on a protective cover. housing components as required. Fit to the rear of the cooktop.
  • Page 14 INSTALL COOKTOP – FLUSH Filter housing Ducting Prepare the countertop for flush Align vertical ducting to the installation. Use a router to cutout outlet on the cooktop before the edges of the countertop to lowering it into the cutout. specified depth (5mm). Ensure all bare edges are sealed.
  • Page 15: Installer Checklist

    INSTALLER CHECKLIST TO BE COMPLETED BY THE INSTALLER GENERAL VENTILATION … … Read safety and warnings in the user guide before operating the cooktop. Ensure all ducting components are taped securely. … … Specified clearance maintained. Check outlets are clear and not obstructed. …...
  • Page 16 FISHERPAYKEL.COM © Fisher & Paykel Appliances 2021. All rights reserved. The models shown in this guide may not be available in all markets and are subject to change at any time. The product specifications in this guide apply to the specific products and models described at the date of issue.