Dual-Purpose Ports; A P P E N D I X B Connector And Cable Specifications; 10/100 Ethernet Management Port; Alarm Input Port - Cisco ME 3400E Hardware Installation Manual

Cisco systems ethernet access switch installation guide
Hide thumbs Also See for Cisco ME 3400E:
Table of Contents

Advertisement

Appendix B
Connector and Cable Specifications

Dual-Purpose Ports

The 10/100/1000 Ethernet ports on the dual-purpose ports use standard RJ-45 connectors.
Figure B-3

10/100 Ethernet Management Port

The 10/100 Ethernet management port uses standard RJ-45 connectors with Ethernet pinouts.
Figure B-4

Alarm Input Port

The alarm input port uses a standard RJ-45 connector. See
more information.
Note
OL-16447-01
10/100/1000 Port Pinouts
Pin
Label
1
TP0+
2
TP0-
3
TP1+
4
TP2+
5
TP2-
6
TP1-
7
TP3+
8
TP3-
10/100 Port Pinouts
Pin
Label
1
RD+
2
RD-
3
TD+
4
NC
5
NC
6
TD-
7
NC
8
NC
We recommend using a shielded cable grounded at both ends for NEBS.
1
2 3
4 5 6 7 8
1
2 3
4 5 6 7 8
"Alarm Input Port" section on page 1-4