Cisco MEM-S2-512MB Installation Notes

Supervisor engine 720 switch processor and route processor memory installation note

Advertisement

Supervisor Engine 720 Switch Processor and
Route Processor Memory Installation Note
Product Number: MEM-S2-512MB=, MEM-MSFC2-512MB=, MEM-S3-1GB=,
MEM-MSFC3-1GB=
This publication describes how to upgrade the dynamic random-access memory (DRAM) dual inline
memory modules (DIMMs) on the Supervisor Engine 720.
Contents
This publication consists of these sections:
Note
For translations of the warnings in this publication, see the
page
Corporate Headquarters:
Cisco Systems, Inc., 170 West Tasman Drive, San Jose, CA 95134-1706 USA
© 2003-2005 Cisco Systems, Inc. All rights reserved.
20.
"Translated Safety Warnings" section on

Advertisement

Table of Contents
loading

Summary of Contents for Cisco MEM-S2-512MB

  • Page 1: Table Of Contents

    Obtaining Additional Publications and Information, page 31 Note For translations of the warnings in this publication, see the “Translated Safety Warnings” section on page Corporate Headquarters: Cisco Systems, Inc., 170 West Tasman Drive, San Jose, CA 95134-1706 USA © 2003–2005 Cisco Systems, Inc. All rights reserved.
  • Page 2: Safety Overview

    Safety Overview Safety Overview Safety warnings appear throughout this publication in procedures that may harm you if performed incorrectly. A warning symbol precedes each warning statement. IMPORTANT SAFETY INSTRUCTIONS Warning This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents.
  • Page 3 Safety Overview Warnung WICHTIGE SICHERHEITSHINWEISE Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und den üblichen Verfahren zur Vorbeugung vor Unfällen vertraut. Suchen Sie mit der am Ende jeder Warnung angegebenen Anweisungsnummer nach der jeweiligen Übersetzung in den übersetzten Sicherheitshinweisen, die zusammen mit diesem Gerät ausgeliefert wurden.
  • Page 4 Safety Overview Varning! VIKTIGA SÄKERHETSANVISNINGAR Denna varningssignal signalerar fara. Du befinner dig i en situation som kan leda till personskada. Innan du utför arbete på någon utrustning måste du vara medveten om farorna med elkretsar och känna till vanliga förfaranden för att förebygga olyckor. Använd det nummer som finns i slutet av varje varning för att hitta dess översättning i de översatta säkerhetsvarningar som medföljer denna anordning.
  • Page 5 Safety Overview Aviso INSTRUÇÕES IMPORTANTES DE SEGURANÇA Este símbolo de aviso significa perigo. Você se encontra em uma situação em que há risco de lesões corporais. Antes de trabalhar com qualquer equipamento, esteja ciente dos riscos que envolvem os circuitos elétricos e familiarize-se com as práticas padrão de prevenção de acidentes. Use o número da declaração fornecido ao final de cada aviso para localizar sua tradução nos avisos de segurança traduzidos que acompanham o dispositivo.
  • Page 6 Safety Overview Supervisor Engine 720 Switch Processor and Route Processor Memory Installation Note 78-15538-02...
  • Page 7 Safety Overview Supervisor Engine 720 Switch Processor and Route Processor Memory Installation Note 78-15538-02...
  • Page 8: Installing The Sp And Rp Memory Upgrade Kit

    Installing the SP and RP Memory Upgrade Kit Installing the SP and RP Memory Upgrade Kit This section is divided into the following topics: Required Tools, page 8 • Removing the Supervisor Engine 720, page 8 • Removing and Installing the DRAM DIMMs, page 11 •...
  • Page 9 Installing the SP and RP Memory Upgrade Kit Always use an ESD wrist strap when handling the Supervisor Engine 720 or coming in contact with Caution internal components. To remove the supervisor engine, follow these steps: Disconnect any network interface cables attached to the supervisor engine. Step 1 Verify that the captive installation screws on all of the modules in the chassis are tight.
  • Page 10 Installing the SP and RP Memory Upgrade Kit Figure 1 Opening the Ejector Levers (Horizontal Chassis Shown) WS-X6624-FXS 24 PORT FXS ANALOG STATION WS-X6624-FXS 24 PORT FXS ANALOG STATION WS-X6348-RJ-45 V 48 PORT 10/100 BASE-T ETHERNET SWITCHING MODULE INPUT OUTPU T FAIL INPUT OUTPU T...
  • Page 11 Installing the SP and RP Memory Upgrade Kit Figure 2 Removing the Module from the Chassis (Horizontal Chassis Shown) WS-X6624-FXS 24 PORT FXS ANALOG STATION WS-X6624-FXS 24 PORT FXS ANALOG STATION WS-X6348-RJ-45 V 48 PORT 10/100 BASE-T ETHERNET SWITCHING MODULE INPUT OUTPU T FAIL...
  • Page 12 Installing the SP and RP Memory Upgrade Kit Figure 3 DRAM DIMM Location on the Supervisor Engine 720 DRAM DIMM Figure 4 Handling a DIMM Supervisor Engine 720 Switch Processor and Route Processor Memory Installation Note 78-15538-02...
  • Page 13 When inserting the DIMM, use firm but not excessive pressure. If you damage a socket, you must Caution return the supervisor engine to Cisco for repair. Press down on the edges of the DIMM until the DIMM clicks into place. (See...
  • Page 14 Installing the SP and RP Memory Upgrade Kit Installing the Supervisor Engine 720 During this procedure, wear grounding wrist straps, and handle modules by the carrier edges only to Caution avoid ESD damage to the module. To reinstall the Supervisor Engine 720 in the chassis, follow these steps: Step 1 Verify that the captive installation screws are tightened on all modules installed in the chassis.
  • Page 15 Installing the SP and RP Memory Upgrade Kit Figure 6 Positioning the Module in a Horizontal Slot Chassis Insert module between slot guides EMI gasket EMI gasket INPUT OUTPU T FAIL INPUT OUTPU T FAIL WS-S UP72 SUP ERV ISO R 720 WIT H INT EGR ATE D SW ITC H FAB RIC Ejector lever fully...
  • Page 16 Installing the SP and RP Memory Upgrade Kit Depending on the orientation of the slots in the chassis (horizontal or vertical), perform one of the Step 3 following two sets of stepsfor positioning the module in a chassis with either horizontal or vertical slots: Horizontal slots Position the supervisor engine in the slot.
  • Page 17 Installing the SP and RP Memory Upgrade Kit Figure 7 Clearing the EMI Gasket in a Horizontal Slot Chassis Press down Press down Gap between the module EMI gasket and the module above it Supervisor Engine 720 Switch Processor and Route Processor Memory Installation Note 78-15538-02...
  • Page 18 Installing the SP and RP Memory Upgrade Kit Vertical slots Position the supervisor engine in the slot. (See Figure 8.) Make sure that you align the sides of the module carrier with the slot guides on the top and bottom of the slot. Carefully slide the supervisor engine into the slot until the EMI gasket along the right edge of the module makes contact with the module in the slot adjacent to it and both ejector levers have closed to approximately 45 degrees with respect to the module faceplate.
  • Page 19 Installing the SP and RP Memory Upgrade Kit Figure 9 Clearing the EMI Gasket in a Vertical Slot Chassis Gap between the module EMI gasket and the module above it STATUS Press left Press left INPUT OUTPUT FAIL INPUT OUTPUT FAIL Using the thumb and forefinger of each hand, grasp the two ejector levers, and exert a slight pressure to the left, deflecting it approximately 0.040 inches (1 mm) creating a small gap between the...
  • Page 20: Translated Safety Warnings

    Translated Safety Warnings Tighten the two captive installation screws on the supervisor engine. Make sure that the ejector levers are fully closed before tightening the captive installation Note screws. Verify that the STATUS LED is lit. Periodically check the STATUS LED. If the STATUS LED changes from orange to green, the module has successfully completed the boot process and is now online.
  • Page 21 Translated Safety Warnings Warnung Blanke Faceplates und Abdeckungen haben drei wichtigen Funktionen: (1) Sie schützen vor gefährlichen Spannungen und Strom innerhalb des Chassis; (2) sie halten elektromagnetische Interferenzen (EMI) zurück, die andere Geräte stören könnten; (3) sie lenken den kühlenden Luftstrom durch das Chassis.
  • Page 22 Translated Safety Warnings Aviso Plaquetas vazias e painéis de proteção têm três funções importantes: impedem a exposição a tensões e correntes elétricas perigosas dentro do chassi; apresentam interferência eletromagnética (EMI) que pode danificar outros equipamentos: direcionam o fluxo do ar refrigerado pelo chassi.
  • Page 23 Translated Safety Warnings Statement 1030—Equipment Installation Only trained and qualified personnel should be allowed to install, replace, or service Warning this equipment. Waarschuwing Deze apparatuur mag alleen worden geïnstalleerd, vervangen of hersteld door bevoegd geschoold personeel. Varoitus Tämän laitteen saa asentaa, vaihtaa tai huoltaa ainoastaan koulutettu ja laitteen tunteva henkilökunta.
  • Page 24 Translated Safety Warnings Advarsel Bare opplært og kvalifisert personell skal foreta installasjoner, utskiftninger eller service på dette utstyret. Aviso Apenas pessoal treinado e qualificado deve ser autorizado a instalar, substituir ou fazer a revisão deste equipamento. ¡Advertencia! Solamente el personal calificado debe instalar, reemplazar o utilizar este equipo. Varning! Endast utbildad och kvalificerad personal bör få...
  • Page 25 Translated Safety Warnings Statement 1034—Backplane Voltage Warning Hazardous voltage or energy is present on the backplane when the system is operating. Use caution when servicing. Waarschuwing Er is gevaarlijke spanning of energie aanwezig op de achterplaat wanneer het systeem bediend wordt.
  • Page 26 Translated Safety Warnings Aviso O sistema em funcionamento emite tensão ou energia elétrica perigosa no painel traseiro. Seja cauteloso ao fazer a manutenção. Advarsel Der er farlig spænding og energi på bagpladen når systemet er i brug. Vær forsigtig under servicering.
  • Page 27: Obtaining Documentation

    Cisco products and to view technical documentation in HTML. With the DVD, you have access to the same documentation that is found on the Cisco website without being connected to the Internet. Certain products also have .pdf versions of the documentation available.
  • Page 28: Documentation Feedback

    Register to receive security information from Cisco. • A current list of security advisories and notices for Cisco products is available at this URL: http://www.cisco.com/go/psirt If you prefer to see advisories and notices as they are updated in real time, you can access a Product Security Incident Response Team Really Simple Syndication (PSIRT RSS) feed from this URL: http://www.cisco.com/en/US/products/products_psirt_rss_feed.html...
  • Page 29: Obtaining Technical Assistance

    Use the Cisco Product Identification (CPI) tool to locate your product serial number before submitting a web or phone request for service. You can access the CPI tool from the Cisco Technical Support & Documentation website by clicking the Tools & Resources link under Documentation & Tools. Choose Cisco Product Identification Tool from the Alphabetical Index drop-down list, or click the Cisco Product Identification Tool link under Alerts &...
  • Page 30: Submitting A Service Request

    Cisco engineer. The TAC Service Request Tool is located at this URL: http://www.cisco.com/techsupport/servicerequest For S1 or S2 service requests or if you do not have Internet access, contact the Cisco TAC by telephone. (S1 or S2 service requests are those in which your production network is down or severely degraded.) Cisco engineers are assigned immediately to S1 and S2 service requests to help keep your business operations running smoothly.
  • Page 31: Obtaining Additional Publications And Information

    Visit Cisco Marketplace, the company store, at this URL: http://www.cisco.com/go/marketplace/ Cisco Press publishes a wide range of general networking, training and certification titles. Both new • and experienced users will benefit from these publications. For current Cisco Press titles and other information, go to Cisco Press at this URL: http://www.ciscopress.com...
  • Page 32 This document is to be used in conjunction with the Catalyst 6500 Series Switch Module Guide. CCSP, CCVP, the Cisco Square Bridge logo, Follow Me Browsing, and StackWise are trademarks of Cisco Systems, Inc.; Changing the Way We Work, Live, Play, and Learn, and iQuick Study are service marks of Cisco Systems, Inc.; and Access Registrar, Aironet, ASIST, BPX, Catalyst,...