Starting Warm Engine - Shindaiwa EB910RT Operator's Manual

Table of Contents

Advertisement

OPERATION

Starting Warm Engine

The starting procedure is the same as Cold Start except DO NOT close the
choke.
1.
Throttle Lever
Move throttle lever (A) to IDLE
position.
2.
Purge Bulb
Pump purge bulb (C) until fuel is
visible. Pump bulb an additional
4 or 5 times.
3.
Recoil Starter
Pull recoil starter handle (D) and
engine should start. Do not use
choke (B).
Note: If engine does not start
after 5 pulls, use cold
start procedures.
30
A
EB910
A
EB910RT
B
D
C
© 09/22 ECHO Incorporated
EB910 / RT
X7501200801

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eb810rt

Table of Contents