Starting Warm Engine

The starting procedure is the same as Cold Start except DO
NOT close the choke.
1. Throttle Lever
Move throttle position lever (A) to IDLE position.
2. Purge Bulb
Pump purge bulb (C) until fuel is visible. Pump bulb an
additional 4 or 5 times.
3. Recoil Starter
Pull recoil starter handle (D) and engine should start. Do not
use choke (B)
Note: If engine does not start after 5 pulls, use cold start
procedures.

Stopping Engine

1. Throttle Lever
Release throttle trigger. Move Throttle Lever (A) forward to
idle position and allow engine to return to idle before shutting
off engine.
2. Throttle Lever
Move Throttle Lever (A) all the way forward to STOP position.
If engine does not stop when stop switch is moved to STOP
position, close choke - COLD START position - to stall
engine. Have your Shindaiwa dealer repair stop switch before using unit again.

Operating Blower

Engine exhaust IS HOT, and contains Carbon Monoxide (CO), a poison gas. Breathing CO can cause
unconsciousness, serious injury, or death. Exhaust can cause serious burns. ALWAYS position
unit so that exhaust is directed away from your face and body.
Always wear safety glasses, hearing protection and a face filter mask or serious personal injury may
result. Do not point the blower pipe in the direction of people or pets.