Remove The Dc Power Supply - Cisco Router ASR 1006 Hardware Installation Manual

Cisco systems router quick start guide
Hide thumbs Also See for Router Cisco ASR 1006:
Table of Contents

Advertisement

6ru_perf2# *Jan 10 06:09:05.023: %CMRP-3-PEM_REMOVE_SHUT: R0/0: cmand:
minutes
*Jan 10 06:09:05.026: %ASR1000_PEM-6-REMPEM_FM: PEM/FM slot P0 removed
*Jan 10 06:09:10.500: %ASR1000_PEM-6-INSPEM_FM: PEM/FM slot P0 inserted
6ru_perf2#
Replace the AC power supply within five minutes or the system will shutdown.
Step 7
You have removed an AC power supply from the Cisco ASR 1006 Router and now must replace the AC power supply within
five minutes.
Insert another AC power supply in power supply Slot 0 or power supply Slot 1 until it is full seated.
Step 1
Tighten the captive screws. Insert the AC power cable.
Step 2
Plug the power supply cable into the power source.
Step 3
Step 4
Place the power supply standby switch in the On (I) position.
Step 5
The power supply LEDs light when power is supplied to the router.
You have completed a live change-out procedure (that is, removing and replacing an AC power supply) for an AC power supply
not operating properly in the Cisco ASR 1006 Router within five minutes.

Remove the DC Power Supply

Before servicing the power supply, switch off the circuit breaker in your equipment area. As an additional precaution,
Step 1
tape the circuit breaker switch in the Off position.
Slip on the ESD-preventative wrist strap that was included in the accessory kit.
Step 2
Step 3
Switch the power supply circuit breaker switch to Off (O).
Step 4
Locate the terminal block on the rear of the chassis on the power supply.
Remove the slotted plastic cover from the terminal block.
Step 5
a. Loosen and remove the single screw on the plastic cover. The plastic cover has slots that help to slide it out diagonally
from the terminal block.
b. Using a nut driver (7/16 size), unscrew the positive kepnut, positive ground cable, and the flat washer, in that order.
The terminal block houses two double-hole barrel lugs.
c. Follow Step 4b and remove the negative ground cable.
The system will shut down in 5
39

Advertisement

Table of Contents
loading

Table of Contents