Site Requirements Guidelines
Table 2-1
Label
United States
Australian
European
Italian
United Kingdom
Note
DC-Powered Systems
In a router to be equipped with DC-input power supplies, observe the following guidelines:
•
Each DC-input power supply requires a dedicated 40A service.
•
For DC power cables, it is recommended that you use 4 AWG, high-strand-count wire
cable with dual hole lugs that fit over M6 (metric) terminals centered 0.625 inch
(15.86 mm) apart.
For a listing of the electrical specifications for the DC-input power supply, see Table 1-10
in Chapter 1.
Figure 2-6 shows the specifications of the lug used for source DC power cable connections.
Note
the metal faceplate of the DC-input power supply, add a length of heat-shrink tubing to this
area of the lug to provide extra insulation.
2-16
Cisco 12008 Gigabit Switch Router Installation and Configuration Guide
AC Power Cord International Options
Description
208 VAC, 60 Hz AC power cord
240 VAC, 50 Hz AC power cord
230 VAC, 50 Hz AC power cord
220 VAC, 50 Hz AC power cord
240 VAC, 50 Hz AC power cord
All source AC power cords are 14 feet (4.27 m) in length.
To prevent the crimp area on the lug (see Figure 2-6) from coming in contact with
Product Number
CAB-GSR12-US=
CAB-GSR12-AU=
CAB-GSR12-EU=
CAB-GSR12-IT=
CAB-GSR12-UK=