Selecting Grid Profile; Ac Battery Charging Profiles - Briggs & Stratton SIMPLIPHI Installation Manual

6kw hybrid inverter
Table of Contents

Advertisement

only operated between two working logics based on defined peak start and end times to
optimize energy usage.
In the Grid-Tie with Backup mode, users can configure the PV power supply priority, charging source
priority, and load supply source priority. See additional settings in Section 12.3.
Grid-Tie: PV power can only feedback to grid. Battery charging is not active.
Off-Grid: PV power only provides power to the loads and charges battery. PV to the grid is
deactivated.
o
Off-Grid (I)
o
Off-Grid (II)
o
Off-Grid (III)
12.2 – Selecting Grid Profile
Please select the grid standard applicable to your region. The default setting for the inverter is North
American standard IEEE1547.2.
Nominal Output Voltage: 120/240V
WARNING!
THE INVERTER AND WILL VIOLATE THE TERMS OF THE WARRANTY.
12.3 – AC Battery Charging Profiles
Based on the operations chosen in Section 12.2, the set-up window may show different operations.
These modes can be established in display programming (Steps 13-26)
Allow AC Charging Duration: This establishes a period of time to allow AC (Grid) to charge the
batteries.
If duration is set to 0:00 – 0:00, a time limitation for AC to charge the battery has not been
established.
AC Output ON/OFF Timer: This sets up the on/off time for AC Output of the inverter.
If setting is 0:00 – 0:00 the setting is disabled.
Allow to Charge Battery: This option is automatically determined by setting in "Charging source". You
cannot modify the setting from this screen.
When "NONE" is selected in the charging source section, this option becomes unchecked as grey
text.
Allow AC to Charge Battery: This option is automatically determined by setting in "Charging source". You
cannot modify the setting from this screen.
When "Grid and PV" or "Grid or PV" is selected in charging source section, this option is by default
selected.
Under Grid-Tie mode, this option is invalid.
Allow to Feed-In to the Grid: This option is only valid under Grid-Tie and Grid-Tie with Backup modes.
© SIMPLIPHI POWER
SELECTING THE WRONG SETTING CAN CAUSE DAMAGE TO
| 28 |