R-410A SEALED SYSTEM REPAIR

Replace The Evaporator Coil Drain Pan

1. Remove unit from the closet.
2. Remove top panel.
3. Remove filter.
4. Remove left and right upper side panels
5. Carefully lift coil up a few inches and support to avoid damage to tubing.
6. Pry up plastic drain pan using putty knife or other suitable tool.
7. Scape off anyt glue or sealant remaining on the unit using putty knife or other suitable tool.
8. Install new pan, evaporator coil, and panels.