Self-contained indoor air conditioner / heat pump
Hide thumbs Also See for VEB42:

Advertisement

Quick Links

VEB42, VHB42, VEB48, VHB48
SELF-CONTAINED INDOOR AIR CONDITIONER / HEAT PUMP
NOTE: Read the entire instruction manual before starting the installation.
SAFETY CONSIDERATIONS
Improper installation, adjustment, alteration, service, maintenance, or use
can cause explosion, fire, electrical shock, or other conditions which may
cause personal injury or property damage. Consult a qualified installer,
service agency, or your distributor or dealer for information and assistance.
The qualified installer or agency must use factory-authorized parts or
accessories when modifying this product. Refer to the individual instructions
packaged with the parts or accessories when installing.
Follow all safety codes. Wear safety glasses and work gloves. Read these
instructions thoroughly and follow all warnings or cautions attached to the
unit. Consult local building codes, the National Electric Code (NEC), and
the Installation Standards, Warm Air Heating and Air Conditioning Systems
ANSI/NFPA 90B for special installation requirements.
Recognize safety information. This is the safety-alert symbol.
you see this symbol on the unit or in instructions and manuals, be alert to
the potential for personal injury.
Understand the signal words DANGER, WARNING, and CAUTION. These
words are used with the safety-alert symbol. DANGER identifies the most
serious hazards which will result in severe personal injury or death.
WARNING signifies hazards which could result in personal injury or death.
CAUTION is used to identify unsafe practices which would result in minor
personal injury or product and property damage. NOTE is used to convey
special or supplemental information or to repeat and emphasize information
previously provided.
Table 1 - Unit Sizes And Available Electric Heat
UNIT
COOLING
SIZE
BTUH
V(E,H)B42
42,000
V(E,H)B48
48,000
FRIEDRICH AIR CONDITIONING CO.
P.O. BOX 1540 • San Antonio, TX 78295
Ph: 210-357-4400 • FAX: 210-357-4485
www.friedrich.com
HEATING
AVAILABLE
BTUH AT 47ºF
KW
41,000
10 or 15
47,000
15 or 20
INSTALLATION
INSTRUCTIONS
Date:
July 2000
Part No: 84016326 (IM010-01)
When
Figure 1 — B-Series VERT-I-PAK
DANGER: Before installing or servicing system, always turn off main
power to system. There may be more than one (1) disconnect switch. Turn
off auxiliary heater power if applicable. Electrical shock can cause personal
injury or death.
INTRODUCTION
The VERT-I-PAK is ETL and c-ETL listed and is available in the cooling/
electric heating sizes shown in Table 1. The VERT-I-PAK units are
approved for upflow installations. They are designed to be installed in
closets.
The VERT-I-PAK is a self-contained unit. All components including outdoor
coil, compressor, and refrigerant tubing are located in a single package.
The units are already piped, charged, and wired. Refer to Figure 2 for basic
unit dimensions.
1

Advertisement

Table of Contents
loading

Summary of Contents for Friedrich VEB42

  • Page 1 INSTALLATION INSTRUCTIONS Date: July 2000 VEB42, VHB42, VEB48, VHB48 Part No: 84016326 (IM010-01) FRIEDRICH AIR CONDITIONING CO. P.O. BOX 1540 • San Antonio, TX 78295 Ph: 210-357-4400 • FAX: 210-357-4485 www.friedrich.com SELF-CONTAINED INDOOR AIR CONDITIONER / HEAT PUMP NOTE: Read the entire instruction manual before starting the installation.
  • Page 2 Figure 2 — V(E,H)B-Series Unit Dimensions (Inches)
  • Page 3: Installation

    INSTALLATION with 1" duct flange; and left side ducted return with 1" duct flange. See The VERT-I-PAK was designed for installation in residential and light Figures 4, 5 & 6. commercial applications. These instructions detail a typical method of installation. Figure 3 shows the typical component location and airflow NOTE: Ducted return air configurations require field fabrication of a duct paths through the unit.
  • Page 4: Indoor And Outdoor Air Requirements

    I. GENERAL RECOMMENDATIONS (DO'S AND DO NOT'S) OUTDOOR AIR • DO read the instructions completely before installation. OUTDOOR AIR INTAKE EXHAUST • DO take time to perform a quality installation. • DO NOT obstruct or restrict indoor or outdoor air paths. •...
  • Page 5: Line Voltage Electrical Wiring

    B. Outdoor Air System VI. LINE VOLTAGE ELECTRICAL WIRING As a completely self-contained system, the Vert-I-Pak requires an adequate DANGER: Electrical shock hazard. Turn OFF electric power at the supply of outdoor air to exchange heat from the outdoor air coil. The outdoor fuse box or service panel before making any electrical connections and air intake and discharge openings are located on the back side of the unit.
  • Page 6 C. Electrical Connections Romex Ground lug and line voltage connection terminals are located behind the Wiring circuit breaker panel of the control box. See Figure 9. Complete the ground Bushings wire connection. After completing ground wire connection, complete line voltage connections. See Figure 10. WARNING: Failure to adhere to minimum wire sizes, maximum over- current protection, disconnect, and grounding requirements can cause personal injury, electric shock, or a fire hazard.
  • Page 7: Thermostat Mounting And Wiring

    VII. THERMOSTAT MOUNTING AND WIRING A. Thermostat Location Level the thermostat. Tighten the two mounting screws. Locate the thermostat about 5 ft. above the floor in an area with good Replace the thermostat cover. circulation at average indoor temperature. Figure 4 — Terminal and Switch Location Figure 11 —...
  • Page 8: Maintenance

    WARNING: Do not vent refrigerant to atmosphere. Recover all C. Wire Thermostat Cable to Unit Terminal Strip refrigerant before system repair or final unit disposal to avoid personal injury Attach thermostat wires to low-voltage terminal block on left side of or death.

This manual is also suitable for:

Vert-i-pak vhb42Vert-i-pak veb48Vert-i-pak vhb48

Table of Contents