Regency Contura RC500EX Owners & Installation Manual page 51

Direct vent gas fireplace
Table of Contents

Advertisement

LP Setting
NG
16. Slide the control module to remote position.
Remote
17. Install the burner. Set the burner aeration
to full open for LP. See aeration adjustment
details in the manual.
18. Open the gas line. Check for gas leaks with
a proper soapy solution or leak detector.
19. Attach the label "This unit has been
converted to LPG" near or on top of the
serial # decal.
20. Replace yellow "NG" label with red "LPG"
label.
21. Reinstall logs, media, door, access panel
and pedestal door. Turn ON the electrical
supply.
22. Turn ON using the remote control (the
remote control is still with the control
module).
23. Check pilot flames. Correct flame pattern
has 2 strong blue flames. Refer to
"Maintenance Instructions" section of the
manual for correct flame patterns.
24. Check operation of flame control.
25. Check for proper flame appearance and
glow on logs.
920-516
2
installation
RC500EX |
51
06.08.22