installation
Vertical Venting with Two (2) 90
One 90
elbow = Two 45
o
Option
V
H
A)
1' Min.
4' Max.
B)
2' Min.
5' Max.
C)
3' Min.
6' Max.
D)
4' Min.
7' Max.
E)
5' Min.
8' Max.
Lengths do not include elbow indicated
Vent restrictor position A (fully open), refer to the "Vent Restric-
tor Position" section.
Vertical Venting with Two (2) 90
One 90
elbow = Two 45
o
Option
H + H1
A)
2' Max.
2' Min.
B)
3' Max.
3' Min.
C)
4' Max.
4' Min.
D)
5' Max.
5' Min.
E)
6' Max.
6' Min.
Lengths do not include elbow indicated
Vent restrictor position A (fully open), refer to the "Vent
Restrictor Position" section.
34
| RC500EX
Elbows
o
elbows.
o
V + V1
With these options, max.
total pipe length is 30 feet
2' Min.
with min. of 6 feet total
vertical and max. 8 feet
3' Min.
total horizontal.
4' Min.
Please note min. 1
foot between 90
5' Min.
elbows is required.
6' Min.
Elbows
o
elbows.
o
V
With these options, maxi-
mum total pipe length is 30
feet with minimum of 6 feet
total vertical and maximum
6 feet total horizontal.
Please note minimum
1 foot between 90
elbows is required.
V1
o
V
o
H1
V
H
H