Pump Performance Charts - Graco XM Series Operation

Plural-component sprayers
Hide thumbs Also See for XM Series:
Table of Contents

Advertisement

Pump Performance Charts

Pump Performance Charts
Calculate Fluid Outlet Pressure
To calculate fluid outlet pressure (MPa/bar/psi) at a specific
fluid flow (lpm/gpm) and operating air pressure (MPa/bar/psi),
use the following instructions and pump data charts.
1.
Locate desired flow along bottom of chart.
2.
Follow vertical line up to intersection with selected fluid
outlet pressure curve. Follow left to scale to read fluid
outlet pressure.
Ratio setpoint has no significant effect on curves in either performance chart.
Air consumption includes turbine alternator; it does not include feed pumps or agitators.
7000
(49.0, 490)
5000
(35.0, 350)
3000
(21.0, 210)
1000
(7.0, 70)
0.0
KEY:
A = 100 psi (0.7 MPa, 7 bar)
B = 70 psi (0.48 MPa, 4.8 bar)
7000
(49.0, 490)
5000
(35.0, 350)
3000
(21.0, 210)
1000
(7.0, 70)
0.0
KEY:
A = 90 psi (0.62 MPa, 6.2 bar)
B = 70 psi (0.48 MPa, 4.8 bar)
102
XM50 Fluid Performance and Air Consumption
A
B
1.0
(3.8)
Fluid Flow in gpm (lpm)
XM70 Fluid Performance and Air Consumption
A
B
1.0
(3.8)
Fluid Flow in gpm (lpm)
Calculate Pump Air Consumption
To calculate pump air consumption (m
specific fluid flow (lpm/gpm) and air pressure (MPa/bar/psi),
use the following instructions and pump data charts.
1.
Locate desired flow along bottom of chart.
2.
Follow vertical line up to intersection with selected air
consumption curve. Follow right to scale to read air
consumption.
A
B
2.0
(7.6)
A
B
2.0
(7.6)
3
/min or scfm) at a
180
(5.0)
140
(3.9)
100
(2.8)
60
(1.7)
20
(0.6)
3.0
(11.4)
180
(5.0)
140
(3.9)
100
(2.8)
60
(1.7)
20
(0.6)
3.0
(11.4)
312359R