Graco XM Series Operation page 67

Plural-component sprayers
Hide thumbs Also See for XM Series:
Table of Contents

Advertisement

Alarm
Code
Alarm Problem
DEAX
Pump does not move in
DEBX
10 minutes.
DFAX
Pump did not stall against
DFBX
fluid pressure on up stroke
only.
DGAX
Pump did not stall against
DGBX
fluid pressure on down
stroke only.
CACP
Display has no signal.
DJAX
Pump motor linear sensor
DJBX
has no signal.
Pump motor linear sensor
is out of range.
DKAX
Pump motor reed switch
DKBX
failure; missing signals
from both switches.
312359R
When Active
Pump Test (Daily Check Recommended)
Park or Pump
Recirculation valves were not
Test
opened to allow flow.
Pump Test
Pump piston check valve,
piston packings, or dosing
valve are not holding fluid
pressure.
Pump Test
Pump inlet check or dose
valve is fouled, or damaged.
General System Component Alarms
Always
No display communication
signal.
Machine powered down in
spray mode.
Always
No linear sensor signal from
motor.
Linear sensor plugged in while
power is on.
Bad connection inside fluid
control module.
Always
Linear sensor is beyond
range.
Sprayer is not properly
grounded.
Always
Bad motor cable connections,
or bad reed switch.
Reed switch cable is plugged
in while power is on.
Bad connection inside fluid
control module.
Cause
Open recirculation valves.
Flush pump. Follow Empty and
Flush Entire System (new
sprayer or end of job), 48.
Recheck. Remove, clean, and
repair lower. See manual 313289.
Remove inlet housing & clean and
inspect.
See your proportioner repair
manual.
Check cable connections. Replace
display.
See your proportioner repair
manual.
Press stop button before turning
off power.
Swap A and B sensors. Replace
sensor if problem follows sensor.
See your proportioner repair
manual.
Power sprayer off and back on. Do
not plug in linear sensor while
power is on.
Replace fluid control module. See
your proportioner repair manual.
Replace sensor or sensor magnet.
See your proportioner repair
manual.
See , page 15.
Swap A and B motor cables.
Replace cable if problem persists.
Otherwise replace reed sensor
assembly. See your proportioner
repair manual.
Power sprayer off and back on. Do
not plug in reed switch cable while
power is on.
Replace fluid control module. See
your proportioner repair manual.
Troubleshooting
Solution
67

Advertisement

Table of Contents
loading

Table of Contents