Graco XM Series Operation page 66

Plural-component sprayers
Hide thumbs Also See for XM Series:
Table of Contents

Advertisement

Troubleshooting
Alarm
Code
Alarm Problem
R4BE
Ratio High B (Overdose
B), system delivering too
much B component.
R5BE
Dosing sizes are not
optimized.
R5DX
Uncalibrated system in
Weight Mode
R9BE
System detected five
R4BE (ratio high B) or five
R1BE (ratio low B) alarms
within five minutes.
Sprayer shuts down for
five minutes to resolve
problem.
66
When Active
Spray
B Dosing valve not closing.
No B restriction at mix
manifold.
Pump filter plugged on A side.
Inlet air dropping below 80 psi
(0.55 MPa, 5.5 bar) while
spraying. B dosing valve not
closing correctly.
Solenoid air regulator set
below 80 psi (0.55 MPa, 5.5
bar)
Spray
Dosing valve is operating near
high or low timing limits.
Spray
System was not calibrated.
Spray
See R4BE or R1BE alarm
causes.
Cause
Perform Pump Test to test for
leakage. Follow Pump and
Metering Test, page 51.
Loosen valve packing nut. See
your proportioner repair manual.
Check air signal at valve top
Repair valve or air solenoid. See
your proportioner repair manual.
Increase B Restriction by turning B
restrictor stem clockwise. Follow
Adjust B Machine Outlet
Restriction, page 42.
Clean filter. See manual 311762.
Use alternate 30 mesh screen.
See your pump manual for part
number.
Check air filters. See manual
313289.
Use larger air hose.
Use larger compressor.
Use smaller gun tips or less guns
to reduce flow rate.
Adjust air regulator.
Adjust mix manifold B restrictor
stem clockwise or counter
clockwise as indicated by bar
graph on restrictor screen. Follow
Adjust B Machine Outlet
Restriction, page 42.
Run the Pump and Metering
Test, page 51, and Batch
Dispense or Ratio Test, page 54
to calibrate system for weight
mode. Run system in volume
mode.
Run system in volume mode.
See R4BE or R1BE alarm
solutions. Flush mixed material if
necessary, and purge off-ratio
mixed material in hose.
Solution
312359R

Advertisement

Table of Contents
loading

Table of Contents