Appendix A
Batch Dispense or Ratio Test
This screen enables users to dispense a selected total
volume of material on ratio. For example, 1000 ml at 4:1
= 800 ml of A + 200 ml of B. The total batch volume can
be selected from the drop down menu.
When the pump is active it flashes in black on the
screen. When the pump completes dispensing it
displays in gray on the screen.
If the system ratio mode is by volume, pressing
will allow the test to be run either by measuring volumes
or weights. If system ratio mode is by weight, then the
displaced materials must be measured by weight.
Confirm Batch Dispense Test
This screen displays when the batch dispense test
completes without error. This screen displays the
selected ratio between the pumps and the volume of
material dispensed from each pump. The gray at the
bottom of the beaker represents the volume of material
dispensed by pump A. The black at the top of the
beaker represents the volume of material dispensed by
pump B.
There are three variations that affect how the screen is
used:
Ratio by Volume Mode - Test by Volume
Enter the volumes of each dispensed material in the
respective input boxes on this screen. If the calculated
ratio is within the ratio tolerance set on the Setup Ratio
Test screen, a check will appear in the box. The results
are entered into the USB logs.
The target ratio by volume for this test is set on the
Setup Home screen on page 77. The tolerance is set on
the Setup Ratio screen on page 79.
System Ratio Mode by Volume - Test by Volume
88
Ratio by Volume Mode - Test by Weight
Enter the weights of each dispensed material in the
respective input boxes on this screen. If calculated ratio
is within the ratio tolerance set on the Setup Ratio Test
screen, a check will appear in the box. The results are
entered into the USB logs.
The target ratio by weight for this test and tolerance is
set on the Setup Ratio Test screen on page 79.
System Ratio Mode by Volume - Test by Weight
Ratio by Weight Mode
Enter the weights of each dispensed material in the
respective input boxes on this screen. The weights must
be entered in grams. If calculated ratio is within the ratio
tolerance set on the Setup Ratio Test screen, a check
will appear in the box. The results are entered into the
USB logs.
The target ratio by weight for this test is set on the Setup
Home screen on page 77. The tolerance is set on the
Setup Ratio Test screen on page 79
System Ratio Mode by Weight